Formerly Geo Rail Chapter 5.3 — Geotechnical Report Preparation
Present lab results in a single master table (Appendix B) with:

| Column | Description |
|---|---|
| Boring ID | Boring identifier |
| Sample ID | Sample number and type |
| Depth (ft) | Top and bottom of sample interval |
| USCS | Unified classification symbol |
| LL / PL / PI | Atterberg limits |
| % Fines | Percent passing No. 200 sieve |
| γ_d (pcf) | Dry unit weight from Proctor or shelby tube |
| w (%) | Natural water content |
| s_u (tsf) | Undrained shear strength (UU triaxial or vane) |
| c' (psf), φ' (°) | Effective strength parameters (CU/CD triaxial) |
| C_c / C_r | Compression indices (consolidation test) |
| c_v (ft²/day) | Coefficient of consolidation |
| σ'_p (tsf) | Preconsolidation pressure |
| k (ft/day) | Hydraulic conductivity |
| CBR (%) | California Bearing Ratio |
| Notes | Test method, remarks |
Completeness: Every sample assigned a lab test on the investigation plan (Chapter 3.9, Section 3.9.7) must appear in the table, even if the result is "not tested" due to sample disturbance, with a note explaining why.