↑ Parent Menu⌂ Main Menu
← Appendix D Typical Soil Properties
GHRM
Railway Ground Hazard Risk Management · Appendices
Sections · click a car to open it

D.11 SPT Corrections and Property Correlations Calculator

Starting values for each soil type, read from the three numbers every boring gives: the SPT blow count, the natural moisture content and the liquid limit. Each table names where its values came from, what they cannot be used for, and which tests should replace them.
Author: Daniel P. Colwell
D.11 SPT Corrections and Property Correlations Calculator

Carter and Bentley's Soil Properties and their Correlations and Look's Handbook of Geotechnical Investigation and Design Tables collect the correlations used when the only data are blow counts and index tests. The calculator applies the standard corrections and then the most widely used correlations, showing more than one where they disagree, so the user sees the spread rather than a single number. Section D.8 explains which follow-up tests replace these values for design.

D.11.1 Corrections and correlations

Equation D-1. Corrected blow counts

N60 = N (ER/60) CB CS CR;  (N1)60 = CN N60,  CN = (Pa/σ'v)0.5 ≤ 1.7
Table D-15: Correlations used by the calculator
PropertyCorrelationSoil
Relative densityDr ≈ [(N1)60/60]0.5 (Skempton)Sand
Friction angleφ' = √(15.4(N1)60) + 20 (Hatanaka and Uchida, GEC 5 form); φ' = 27.1 + 0.3(N1)60 − 0.00054(N1)60² (Peck et al.)Sand
Drained modulusEs/Pa ≈ 10 N60 clean NC sand (5 silty, 15 OC)Sand
Undrained strengthsu = f1N60, f1 about 135 psf (6.5 kPa) at PI 15 to 92 psf (4.4 kPa) at PI ≥ 40 (Stroud)Clay
Compression index0.009(LL − 10); 0.01(LL − 13); 0.012 wn (EM 1110-1-1904)Clay

D.11.2 Worked examples

Table D-16: Sand and clay samples from a railroad boring (calculator output)
SampleDataResults
Sand at 12 ft, water at 6 ftN = 14, ER 80%N60 15.9; (N1)60 22.1; medium dense; φ' 33.5 deg to 38.4 deg; Es about 336 ksf
Clay at 12 ft, PI 25, LL 45, w 30%N = 9, ER 80%N60 10.2; stiff; su about 1,206 psf; Cc 0.32 to 0.36

Open the SPT correlations calculator →
SPT energy, rod, borehole, sampler and overburden corrections, then relative density, friction angle, modulus, undrained strength and compression index estimates.

D.11.3 Sources in the library

These documents are in the reference library. The method summaries above are paraphrased; equations are standard forms.

← Previous · Appendices Appendices
Next · Appendices → Appendix F — Analytical Equations