Moisture content and the Atterberg limits are cheap, fast and repeatable, and they are often more informative than the blow count in soft and medium fine-grained soils. Run them on every fine-grained sample.
Eq. D-8
| LI | Condition | Typical su of the remolded soil (psf, Eq. D-9) | Engineering meaning |
|---|---|---|---|
| > 1.0 | Above the liquid limit | < 35 | Very soft, sensitive or quick if structure is disturbed; normally consolidated or underconsolidated; expect large settlement |
| 0.75–1.0 | Near the liquid limit | 35–110 | Soft; normally consolidated |
| 0.5–0.75 | Upper plastic range | 110–360 | Medium stiff |
| 0.25–0.5 | Mid plastic range | 360–1,100 | Stiff; often lightly overconsolidated |
| 0–0.25 | Near the plastic limit | 1,100–3,550 | Very stiff; overconsolidated or desiccated |
| < 0 | Below the plastic limit | > 3,550 | Hard; heavily overconsolidated, desiccated or cemented; check for swell |
Eq. D-9 (after Wroth and Wood 1978: about 35 psf at the liquid limit and about 3,550 psf at the plastic limit)
Source: Liquidity index: ASTM D4318 definitions; behavior after Terzaghi, Peck and Mesri (1996) and Mitchell and Soga (2005). Eq. D-9 gives remolded strength; undisturbed strength of structured or overconsolidated clay can be several times higher.
Eq. D-10 (Terzaghi and Peck 1967; Koppula 1981; Mesri and Godlewski 1977; wn in %)
| USCS group | Typical LL | Typical wn below water table (%) | Cc | Cr | cv (ft2/day) | Typical k (ft/day) |
|---|---|---|---|---|---|---|
| ML | 25–45 | 15–35 | 0.10–0.30 | 0.01–0.05 | 0.5–20 | 0.003–3 |
| CL | 25–50 | 15–40 | 0.15–0.40 | 0.02–0.06 | 0.1–2 | 0.0003–0.03 |
| MH | 50–80 | 30–60 | 0.30–0.80 | 0.03–0.10 | 0.05–2 | 0.0003–0.03 |
| CH | 50–100 | 30–70 | 0.40–1.0 | 0.05–0.15 | 0.01–0.5 | 0.00003–0.003 |
| OL / OH | 35–80 | 40–150 | 0.40–1.5 | 0.05–0.20 | 0.02–1 | 0.0003–0.03 |
Ranges compiled from Holtz, Kovacs and Sheahan (2011), Terzaghi, Peck and Mesri (1996) and NAVFAC DM-7.01 (1986).
Below the water table a fine-grained soil is saturated, so its moisture content fixes its void ratio and unit weight:
Eq. D-11 (S = 100%; γw = 62.4 pcf)
| w (%) | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 80 | 100 |
|---|---|---|---|---|---|---|---|---|---|
| Void ratio, e | 0.41 | 0.54 | 0.68 | 0.81 | 1.08 | 1.35 | 1.62 | 2.16 | 2.70 |
| γsat (pcf) | 138 | 131 | 126 | 121 | 113 | 108 | 103 | 96 | 91 |
| γd (pcf) | 120 | 109 | 101 | 93 | 81 | 72 | 64 | 53 | 46 |
Computed from Eq. D-11. For each 0.1 change in Gs, γsat changes by about 1 to 3 pcf. Use Gs = 2.60 to 2.65 for soils with organic content and 2.75 to 2.80 for micaceous or iron-rich soils.
Follow-up testing: Natural moisture (ASTM D2216) on every sample; Atterberg limits (ASTM D4318, wet preparation) on each fine-grained stratum; specific gravity (ASTM D854) where unit weight governs; one-dimensional consolidation (ASTM D2435 or D4186) on tube samples under embankments and structures; organic content (ASTM D2974) where w or color suggest organics.