Appendix D — Typical Soil Properties from Blow Counts, Moisture Content and Liquid Limit

Starting values for each soil type, read from the three numbers every boring gives: the SPT blow count, the natural moisture content and the liquid limit. Each table names where its values came from, what they cannot be used for, and which tests should replace them.
Author: Daniel P. Colwell

Primary References: Terzaghi and Peck (1967); Peck, Hanson and Thornburn (1974); Kulhawy and Mayne (1990), EPRI EL-6800; NAVFAC DM-7.01 (1986); Bowles (1996); Holtz, Kovacs and Sheahan (2011); Skempton (1986); Stroud (1974); Wroth and Wood (1978); ASTM D1586, D2216, D2487, D4318.

Typical Values for This Chapter — from the GHRM Soil & Rock Properties Database

The full database extends this appendix with values and ranges from the library references. English units; every value cites its library source, table and page. For preliminary design and checking test results, not a substitute for site testing.

Consistency, density and SPT (60 values)
PropertySoil / materialClassConditionLowTypicalHighUnitsSource
Undrained shear strengthClayCL-CHVery soft251psfLOOK T2.14 / 5.3, p.50
Undrained shear strengthClayCL-CHSoft251386.5522psfLOOK T2.14 / 5.3, p.50
Undrained shear strengthClayCL-CHFirm5227831,044psfLOOK T2.14 / 5.3, p.50
Undrained shear strengthClayCL-CHStiff1,0441,5662,088psfLOOK T2.14 / 5.3, p.50
Undrained shear strengthClayCL-CHVery stiff2,0883,1324,177psfLOOK T2.14 / 5.3, p.50
Undrained shear strengthClayCL-CHHard4,177psfLOOK T2.14 / 5.3, p.50
Unconfined compressive strengthCohesive soilCL-CHVery soft (N < 2)0.25tsfIDOT T4.4.6.1.2-2, p.119
Unconfined compressive strengthCohesive soilCL-CHSoft (N = 2–4)0.250.3750.5tsfIDOT T4.4.6.1.2-2, p.119
Unconfined compressive strengthCohesive soilCL-CHMedium stiff (N = 4–8)0.50.751tsfIDOT T4.4.6.1.2-2, p.119
Unconfined compressive strengthCohesive soilCL-CHStiff (N = 8–15)11.52tsfIDOT T4.4.6.1.2-2, p.119
Unconfined compressive strengthCohesive soilCL-CHVery stiff (N = 15–30)234tsfIDOT T4.4.6.1.2-2, p.119
Unconfined compressive strengthCohesive soilCL-CHHard (N > 30)468tsfIDOT T4.4.6.1.2-2, p.119
SPT N-valueCohesive soilCL-CHVery soft00.51blows/ftGEC5 T23, p.137
SPT N-valueCohesive soilCL-CHSoft234blows/ftGEC5 T23, p.137
SPT N-valueCohesive soilCL-CHMedium stiff56.58blows/ftGEC5 T23, p.137
SPT N-valueCohesive soilCL-CHStiff91215blows/ftGEC5 T23, p.137
SPT N-valueCohesive soilCL-CHVery stiff162330blows/ftGEC5 T23, p.137
SPT N-valueCohesive soilCL-CHHard3145.560blows/ftGEC5 T23, p.137
SPT N-valueCohesive soilCL-CHVery hard60blows/ftGEC5 T23, p.137
SPT N-valueGranular soilGW-SMVery loose4blows/ftLOOK T2.15, p.50
Relative densityGranular soilGW-SMVery loose15%LOOK T2.15, p.50
SPT N-valueGranular soilGW-SMLoose4710blows/ftLOOK T2.15, p.50
Relative densityGranular soilGW-SMLoose152535%LOOK T2.15, p.50
SPT N-valueGranular soilGW-SMMedium dense102030blows/ftLOOK T2.15, p.50
Relative densityGranular soilGW-SMMedium dense355065%LOOK T2.15, p.50
SPT N-valueGranular soilGW-SMDense304050blows/ftLOOK T2.15, p.50
Relative densityGranular soilGW-SMDense657585%LOOK T2.15, p.50
SPT N-valueGranular soilGW-SMVery dense50blows/ftLOOK T2.15, p.50
Relative densityGranular soilGW-SMVery dense85%LOOK T2.15, p.50
Undrained shear strengthClayCL-CHVery soft418psfCRAIG T4.1, p.121
Undrained shear strengthClayCL-CHSoft418626.5835psfCRAIG T4.1, p.121
Undrained shear strengthClayCL-CHFirm8351,2001,566psfCRAIG T4.1, p.121
Undrained shear strengthClayCL-CHStiff1,5662,3503,133psfCRAIG T4.1, p.121
Undrained shear strengthClayCL-CHVery stiff3,1334,7006,266psfCRAIG T4.1, p.121
Undrained shear strengthClayCL-CHHard6,266psfCRAIG T4.1, p.121
Density index (relative density)SandSP-SWVery loose (N = 0–4)07.515%CRAIG T8.3, p.309
Normalized SPT valueSandSP-SWVery loose (N = 0–4)01.53blows/ftCRAIG T8.3, p.309
Density index (relative density)SandSP-SWLoose (N = 4–10)152535%CRAIG T8.3, p.309
Normalized SPT valueSandSP-SWLoose (N = 4–10)35.58blows/ftCRAIG T8.3, p.309
Density index (relative density)SandSP-SWMedium dense (N = 10–30)355065%CRAIG T8.3, p.309
Normalized SPT valueSandSP-SWMedium dense (N = 10–30)816.525blows/ftCRAIG T8.3, p.309
Density index (relative density)SandSP-SWDense (N = 30–50)657585%CRAIG T8.3, p.309
Normalized SPT valueSandSP-SWDense (N = 30–50)2533.542blows/ftCRAIG T8.3, p.309
Density index (relative density)SandSP-SWVery dense (N > 50)8592.5100%CRAIG T8.3, p.309
Normalized SPT valueSandSP-SWVery dense (N > 50)425058blows/ftCRAIG T8.3, p.309
Presumed allowable bearing value (BS 8004)Dense gravel, or dense sand and gravelGW, GP, SWFooting width ≥ 3.3 ft; groundwater ≥ B below base12.5ksfCURTIN T1.1, p.5
Presumed allowable bearing value (BS 8004)Medium dense gravel, or sand and gravelGW, GP, SWFooting width ≥ 3.3 ft; groundwater ≥ B below base4.28.312.5ksfCURTIN T1.1, p.5
Presumed allowable bearing value (BS 8004)Loose gravel, or sand and gravelGW, GP, SWFooting width ≥ 3.3 ft; groundwater ≥ B below base4.2ksfCURTIN T1.1, p.5
Presumed allowable bearing value (BS 8004)Compact sandSW, SPFooting width ≥ 3.3 ft; groundwater ≥ B below base6.3ksfCURTIN T1.1, p.5
Presumed allowable bearing value (BS 8004)Medium dense sandSW, SPFooting width ≥ 3.3 ft; groundwater ≥ B below base2.14.26.3ksfCURTIN T1.1, p.5
Presumed allowable bearing value (BS 8004)Loose sandSW, SPFooting width ≥ 3.3 ft; groundwater ≥ B below base2.1ksfCURTIN T1.1, p.5
Presumed allowable bearing value (BS 8004)Very stiff boulder clay and hard clayCL, CHFooting width ≥ 3.3 ft; groundwater ≥ B below base6.39.412.5ksfCURTIN T1.1, p.5
Presumed allowable bearing value (BS 8004)Stiff clayCL, CHFooting width ≥ 3.3 ft; groundwater ≥ B below base3.14.76.3ksfCURTIN T1.1, p.5
Presumed allowable bearing value (BS 8004)Firm clayCL, CHFooting width ≥ 3.3 ft; groundwater ≥ B below base1.62.353.1ksfCURTIN T1.1, p.5
Presumed allowable bearing value (BS 8004)Soft clay and siltCL, CH, MLFooting width ≥ 3.3 ft; groundwater ≥ B below base1.6ksfCURTIN T1.1, p.5
Undrained strength of clay from hand-sample identificationClayVery softExtrudes between fingers420psfATKINSON T5.2, p.61
Undrained strength of clay from hand-sample identificationClaySoftEasily molded in fingers420630840psfATKINSON T5.2, p.61
Undrained strength of clay from hand-sample identificationClayFirmMolded by strong finger pressure8401,2051,570psfATKINSON T5.2, p.61
Undrained strength of clay from hand-sample identificationClayStiffCannot be molded in fingers1,5701,8302,090psfATKINSON T5.2, p.61
Undrained strength of clay from hand-sample identificationClayVery stiffCan be indented by thumbnail3,130psfATKINSON T5.2, p.61
Open this set in the database ↗
Unit weight (Look and Carter & Bentley) (63 values)
PropertySoil / materialClassConditionLowTypicalHighUnitsSource
Dry unit weightSands and gravelsGW-SPVery loose89.1pcfLOOK T7.3, p.104
Saturated unit weightSands and gravelsGW-SPVery loose108.2pcfLOOK T7.3, p.104
Dry unit weightSands and gravelsGW-SPLoose95.5pcfLOOK T7.3, p.104
Saturated unit weightSands and gravelsGW-SPLoose114.6pcfLOOK T7.3, p.104
Dry unit weightSands and gravelsGW-SPMedium dense108.2pcfLOOK T7.3, p.104
Saturated unit weightSands and gravelsGW-SPMedium dense127.3pcfLOOK T7.3, p.104
Dry unit weightSands and gravelsGW-SPDense121pcfLOOK T7.3, p.104
Saturated unit weightSands and gravelsGW-SPDense133.7pcfLOOK T7.3, p.104
Dry unit weightSands and gravelsGW-SPVery dense133.7pcfLOOK T7.3, p.104
Saturated unit weightSands and gravelsGW-SPVery dense140pcfLOOK T7.3, p.104
Dry unit weightSandsSP / SWLoose, uniformly graded89.1pcfLOOK T7.3, p.104
Saturated unit weightSandsSP / SWLoose, uniformly graded108.2pcfLOOK T7.3, p.104
Dry unit weightSandsSP / SWLoose, well graded101.9pcfLOOK T7.3, p.104
Saturated unit weightSandsSP / SWLoose, well graded121pcfLOOK T7.3, p.104
Dry unit weightSandsSP / SWDense, uniformly graded114.6pcfLOOK T7.3, p.104
Saturated unit weightSandsSP / SWDense, uniformly graded127.3pcfLOOK T7.3, p.104
Dry unit weightSandsSP / SWDense, well graded121pcfLOOK T7.3, p.104
Saturated unit weightSandsSP / SWDense, well graded133.7pcfLOOK T7.3, p.104
Dry unit weightCohesive soilsCL-CH / OL-OHSoft – organic50.9pcfLOOK T7.3, p.104
Saturated unit weightCohesive soilsCL-CH / OL-OHSoft – organic89.1pcfLOOK T7.3, p.104
Dry unit weightCohesive soilsCL-CH / OL-OHSoft – non-organic76.4pcfLOOK T7.3, p.104
Saturated unit weightCohesive soilsCL-CH / OL-OHSoft – non-organic101.9pcfLOOK T7.3, p.104
Dry unit weightCohesive soilsCL-CH / OL-OHStiff101.9pcfLOOK T7.3, p.104
Saturated unit weightCohesive soilsCL-CH / OL-OHStiff114.6pcfLOOK T7.3, p.104
Dry unit weightCohesive soilsCL-CH / OL-OHHard114.6pcfLOOK T7.3, p.104
Saturated unit weightCohesive soilsCL-CH / OL-OHHard127.3pcfLOOK T7.3, p.104
Dry unit weightBroken rock – soft sedimentary (chalk, shale, siltstone, coal)RockfillCompacted76.4pcfLOOK T7.3, p.104
Saturated unit weightBroken rock – soft sedimentary (chalk, shale, siltstone, coal)RockfillCompacted114.6pcfLOOK T7.3, p.104
Dry unit weightBroken rock – hard sedimentary (conglomerate, sandstone)RockfillCompacted89.1pcfLOOK T7.3, p.104
Saturated unit weightBroken rock – hard sedimentary (conglomerate, sandstone)RockfillCompacted121pcfLOOK T7.3, p.104
Dry unit weightBroken rock – metamorphicRockfillCompacted114.6pcfLOOK T7.3, p.104
Saturated unit weightBroken rock – metamorphicRockfillCompacted127.3pcfLOOK T7.3, p.104
Dry unit weightBroken rock – igneousRockfillCompacted108.2pcfLOOK T7.3, p.104
Saturated unit weightBroken rock – igneousRockfillCompacted133.7pcfLOOK T7.3, p.104
Bulk (saturated) unit weightSand and gravelGW-SPVery loose108.2111.4114.6pcfCB T3.1, p.79
Dry unit weightSand and gravelGW-SPVery loose82.885.989.1pcfCB T3.1, p.79
Bulk (saturated) unit weightSand and gravelGW-SPLoose114.6117.8121pcfCB T3.1, p.79
Dry unit weightSand and gravelGW-SPLoose89.192.395.5pcfCB T3.1, p.79
Bulk (saturated) unit weightSand and gravelGW-SPMedium dense121124.2127.3pcfCB T3.1, p.79
Dry unit weightSand and gravelGW-SPMedium dense95.5105114.6pcfCB T3.1, p.79
Bulk (saturated) unit weightSand and gravelGW-SPDense127.3133.7140pcfCB T3.1, p.79
Dry unit weightSand and gravelGW-SPDense108.2117.8127.3pcfCB T3.1, p.79
Bulk (saturated) unit weightSand and gravelGW-SPVery dense140143.2146.4pcfCB T3.1, p.79
Dry unit weightSand and gravelGW-SPVery dense127.3133.7140pcfCB T3.1, p.79
Bulk (saturated) unit weightPoorly graded sandsSPNatural108.2114.6121pcfCB T3.1, p.79
Dry unit weightPoorly graded sandsSPNatural82.889.295.5pcfCB T3.1, p.79
Bulk (saturated) unit weightWell-graded sandsSWNatural114.6130.5146.4pcfCB T3.1, p.79
Dry unit weightWell-graded sandsSWNatural89.1114.5140pcfCB T3.1, p.79
Bulk (saturated) unit weightWell-graded sand–gravel mixturesGW / SWNatural121133.7146.4pcfCB T3.1, p.79
Dry unit weightWell-graded sand–gravel mixturesGW / SWNatural95.5117.8140pcfCB T3.1, p.79
Bulk (saturated) unit weightClay – unconsolidated mudsOH / CHNatural101.9105.1108.2pcfCB T3.1, p.79
Dry unit weightClay – unconsolidated mudsOH / CHNatural57.363.670pcfCB T3.1, p.79
Bulk (saturated) unit weightClay – soft, open-structuredCL-CHNatural108.2114.6121pcfCB T3.1, p.79
Dry unit weightClay – soft, open-structuredCL-CHNatural7079.589.1pcfCB T3.1, p.79
Bulk (saturated) unit weightClay – firm or stiff, normally consolidatedCL-CHNatural114.6127.3140pcfCB T3.1, p.79
Dry unit weightClay – firm or stiff, normally consolidatedCL-CHNatural82.8101.9121pcfCB T3.1, p.79
Bulk (saturated) unit weightGlacial till (boulder clay)CL / SC / GCNatural127.3140.1152.8pcfCB T3.1, p.79
Dry unit weightGlacial till (boulder clay)CL / SC / GCNatural108.2124.1140pcfCB T3.1, p.79
Bulk (saturated) unit weightTropical red claysCL-MHNatural108.2120.9133.7pcfCB T3.1, p.79
Dry unit weightTropical red claysCL-MHNatural82.898.7114.6pcfCB T3.1, p.79
Specific gravity of solidsQuartz sandSP / SW2.65–CB T3.1, p.79
Specific gravity of solidsCalcareous sandSP / SW2.642.6752.71–CB T3.1, p.79
Specific gravity of solidsMost clay mineralsCL-CH2.672.72.73–CB T3.1, p.79
Open this set in the database ↗
References (7)
  1. ATKINSON – Atkinson, J. (2007). The Mechanics of Soils and Foundations, 2nd ed. Taylor & Francis.
  2. CB – Carter, M. & Bentley, S.P. (2016). Soil Properties and their Correlations, 2nd ed. Wiley.
  3. CRAIG – Craig, R.F. (2004). Craig's Soil Mechanics, 7th ed. Spon Press.
  4. CURTIN – Curtin, W.G., Shaw, G., Parkinson, G.I., Golding, J.M. & Seward, N.J. (2006). Structural Foundation Designers' Manual, 2nd ed. Blackwell.
  5. GEC5 – Sabatini, P.J. et al. (2002). FHWA-IF-02-034 (superseded by GEC 5, Geotechnical Site Characterization, FHWA-NHI-16-072 (2017)), Geotechnical Engineering Circular No. 5: Evaluation of Soil and Rock Properties.
  6. IDOT – Illinois DOT (2015). Geotechnical Manual.
  7. LOOK – Look, B.G. (2007). Handbook of Geotechnical Investigation and Design Tables. Taylor & Francis.

Full database  ·  Laboratory tests  ·  Download Excel  ·  Library documents for this chapter  ·  Calculators for this chapter

Further reading — ICE Manual of Geotechnical Engineering
The chapters below cover the same ground in more depth. They are cited, not reproduced; see Appendix G for the full cross-reference and edition notes.
D.0 How to Use This Appendix

Every boring produces three numbers long before the laboratory program is finished: the Standard Penetration Test blow count (N), the natural moisture content (w) and, for fine-grained soils, the liquid limit (LL) and plastic limit (PL). This appendix turns those numbers into typical engineering properties for each soil type, so a preliminary analysis can start the day the boring logs arrive.

Use it in this order:

  1. Classify the soil (USCS group, Chapter 2.2, Section 2.2.4). Coarse-grained soils use Section D.2; fine-grained soils use Sections D.3 and D.4; silts also see Chapter 2.4; organic soils use Section D.5.
  2. Correct the blow count to N60 and, for sands, to (N1)60 (Section D.1).
  3. Read the consistency or density term and the property ranges from the tables.
  4. Check the moisture content against the Atterberg limits (liquidity index, Section D.4). Where the blow count and the moisture content point to different consistencies, use the weaker value and flag it for testing.
  5. Record the source printed under each table, and list the follow-up tests needed to replace the typical value (Section D.8).
Every value in this appendix is a typical value from published correlations, not a test result. State in calculations and reports that a parameter was "estimated from Appendix D, Table D-x," and replace it with site test data before final design. Section D.7 lists the general limitations; each table also has its own.

All values are in English units: unit weight in pcf, stress and strength in psf (or ksf), modulus in ksf, permeability in ft/day.

D.1 Blow Count Corrections and Description Terms

The tables in this appendix are based on N60, the blow count corrected to 60% of the theoretical hammer energy. Field blow counts must be corrected first; an automatic hammer delivers 80% to 95% energy, so its raw N reads low against the correlations.

N60 = Nfield · Em60 · CB · CS · CR      (N1)60 = CN N60,   CN = √(2,117/σ′v) ≤ 1.7

Eq. D-1 (Skempton 1986; Liao and Whitman 1986; σ′v in psf)

Table D-1: SPT Correction Factors
FactorConditionValue
Em (hammer efficiency, %)Donut hammer / safety hammer (rope and cathead) / automatic trip hammer45 / 60 / 80–95 (measure per ASTM D4633, withdrawn 2025 where possible)
CB (borehole diameter)2.5–4.5 in. / 6 in. / 8 in.1.00 / 1.05 / 1.15
CS (sampler)Standard sampler / sampler without liners1.0 / 1.1–1.3
CR (rod length)< 13 ft / 13–20 ft / 20–33 ft / > 33 ft0.75 / 0.85 / 0.95 / 1.0

Source: Skempton (1986); Youd et al. (2001); ASTM D1586 and D4633 (withdrawn 2025). Full procedure in Chapter 4.1, Section 4.1.3.

Table D-2: Relative Density of Coarse-Grained Soils from N60
DescriptionN60 (blows/ft)(N1)60Relative density, Dr (%)Field feel
Very loose0–40–30–15Easily penetrated with a ½-in. bar pushed by hand
Loose5–103–815–35Easily penetrated with a ½-in. bar
Medium dense11–308–2535–65Penetrated about 1 ft with a ½-in. bar driven by a 5-lb hammer
Dense31–5025–4265–85Penetrated a few inches with a driven ½-in. bar
Very dense> 50> 4285–100Penetrated only a fraction of an inch with a driven bar

Source: Terzaghi and Peck (1948, 1967); (N1)60 bands after Skempton (1986). Dr can also be estimated from Dr = √[(N1)60/46] (Idriss and Boulanger 2008).

Table D-3: Consistency of Fine-Grained Soils from N60
ConsistencyN60 (blows/ft)Unconfined compressive strength, qu (psf)Undrained shear strength, su (psf)Field feel
Very soft0–2< 500< 250Extrudes between fingers when squeezed
Soft3–4500–1,000250–500Molded by light finger pressure
Medium stiff5–81,000–2,000500–1,000Molded by strong finger pressure
Stiff9–152,000–4,0001,000–2,000Indented by thumb
Very stiff16–304,000–8,0002,000–4,000Indented by thumbnail
Hard> 30> 8,000> 4,000Difficult to indent with thumbnail

Source: Terzaghi and Peck (1967); field descriptions per ASTM D2488. su = qu/2.

Limitations. SPT blow counts in clay are a crude measure of strength: the scatter between N and su is commonly a factor of two in either direction. Blow counts in gravel are inflated by large particles, and in saturated silt and fine sand they are affected by pore pressure during driving. Blow counts from a borehole that was not kept full of fluid below the water table can read very low because of heave at the bottom of the hole.
D.2 Coarse-Grained Soils (Gravels and Sands)

For gravels and sands, the blow count controls the estimate. Moisture content has little effect on the strength of clean coarse soils, but it is needed for unit weight above the water table.

Table D-4: Typical Properties of Clean Sands (SW, SP) by Density
PropertyVery looseLooseMedium denseDenseVery dense
N60 (blows/ft)0–45–1011–3031–50> 50
Friction angle, φ′ (deg)26–2929–3131–3636–4141–45
Moist unit weight, γ (pcf)90–10095–110105–120115–130120–135
Saturated unit weight, γsat (pcf)110–118115–122120–128125–135130–140
Natural moisture above water table (%)3–153–153–123–103–10
Young's modulus, Es (ksf)100–200200–500500–1,0001,000–1,7001,700–2,500
Coefficient of subgrade reaction, ks, 1-ft plate, above / below water table (pci)< 45 / < 3045 / 30150 / 95580 / 350> 580 / > 350

Source: φ′: Peck, Hanson and Thornburn (1974) and NAVFAC DM-7.01 (1986). Unit weights: NAVFAC DM-7.01 and Holtz, Kovacs and Sheahan (2011). Es: Bowles (1996). ks: Terzaghi (1955) for a 1-ft square plate (his recommended 40, 130 and 500 tons/ft³ for loose, medium dense and dense sand above the water table and 25, 80 and 300 tons/ft³ submerged, converted to pci); scale to the loaded width before use. These are vertical plate values, not the p-y modulus constants used for laterally loaded piles.

Table D-5: Adjustments for Other Coarse-Grained Groups
USCS groupφ′ adjustment to Table D-4Unit weight adjustmentPermeability, k (ft/day)Notes
GW, GP (gravels)+2° to +4°+5 to +10 pcf300–3,000 (GP), 30–300 (GW)N inflated by cobbles; discount refusal blows
GM, GC (silty, clayey gravel)0° to +2°+5 pcf0.003–3Drainage and frost behavior controlled by fines
SW, SP (clean sand)Table D-4 as given—3–300 (SP fine sand 3–30)—
SM (silty sand)−2° to −4°−0 to −5 pcf0.03–3See Chapter 2.4 for silt-controlled behavior; liquefiable when loose and saturated
SC (clayey sand)−3° to −6°; c′ = 0–200 psf—0.0003–0.03Moisture-sensitive; use D.3 for strength if fines are plastic and exceed about 30%

Source: Holtz, Kovacs and Sheahan (2011); NAVFAC DM-7.01 (1986); USACE EM 1110-2-1901 (permeability).

Correlations

φ′ ≈ 27.1 + 0.3 (N1)60 − 0.00054 (N1)602

Eq. D-2 (Peck, Hanson and Thornburn 1974, as fitted by Wolff 1989)

φ′ ≈ tan−1[N60 / (12.2 + 20.3 σ′v/pa)]0.34     pa = 2,117 psf

Eq. D-3 (Kulhawy and Mayne 1990; Schmertmann 1975)

Eq. D-2 uses the overburden-corrected blow count, as the Peck, Hanson and Thornburn chart does; it gives about 28° at (N1)60 = 4, 30° at 10, 33° at 20, 36° at 30 and 38° at 40. Eq. D-3 uses N60 and σ′v directly and is a useful cross-check below about 20 ft. Hatanaka and Uchida (1996), in the FHWA GEC 5 form for 60% energy, φ′ = √[15.4 (N1)60] + 20, gives higher values (about 37.5° at (N1)60 = 20; the original √(20 N1) + 20 is for Japanese SPT energy) and is calibrated on high-quality frozen samples of clean sand; cap it at 45° and do not use it for silty sands.

Es (ksf) ≈ 10 (N60 + 15)   (sand)      Es (ksf) ≈ 6.3 (N60 + 6)   (silty or clayey sand)

Eq. D-4 (after Bowles 1996, converted from kPa)

Eq. D-4 and the Es/pa ≈ 10 N60 form used by the calculator (Kulhawy and Mayne 1990) give values near the lower end of the Table D-4 ranges for medium dense and denser sand; the spread is typical of modulus correlations, and the lower value is the safer one for settlement.

Limitations. Values are for uncemented, normally consolidated, predominantly quartz sands. Cemented, calcareous, micaceous or crushable sands, and overconsolidated or aged deposits, can fall well outside these ranges. φ′ correlations do not apply to gravel with cobbles, where blow counts are unreliable. The moduli are for static loading at moderate strain; track and machine-foundation problems at small strain need shear-wave velocity (Chapter 5.1, Section 5.1.6).

Follow-up testing: Grain-size analysis (ASTM D6913) on every sample; energy measurement of the SPT hammer (ASTM D4633, withdrawn 2025); direct shear (ASTM D3080) on reconstituted samples at field density; CPTu soundings for continuous density profile; field permeability tests where drainage or dewatering governs.

D.3 Fine-Grained Soils: Strength and Unit Weight from Blow Counts
Table D-6: Typical Properties of Fine-Grained Soils by Consistency
PropertyVery softSoftMedium stiffStiffVery stiffHard
N60 (blows/ft)0–23–45–89–1516–30> 30
Undrained strength, su (psf)< 250250–500500–1,0001,000–2,0002,000–4,000> 4,000
Saturated unit weight, γsat (pcf)95–110100–115110–120115–125120–130125–135
Typical natural moisture, w, in CL (%)> 4030–4025–3218–2814–22< 16
Typical liquidity index, LI> 1.00.75–1.00.5–0.750.25–0.50–0.25< 0
Young's modulus, Eu (undrained, ksf)< 5050–150150–300300–600600–1,200> 1,200
Coefficient of subgrade reaction, ks (pci, 1-ft plate)——< 6060–115115–230> 230

Source: Consistency and su: Terzaghi and Peck (1967). Unit weights: NAVFAC DM-7.01 (1986). Eu = 200 to 500 su for CL/CH (Duncan and Buchignani 1976), shown here at about 300 su. ks: Terzaghi (1955). Moisture and LI ranges are typical of inorganic lean clay and are given for cross-checking only.

su (psf) ≈ f1 · N60,   f1 ≈ 90 to 135 psf per blow

Eq. D-5 (Stroud 1974; f1 about 135 psf for PI ≈ 15 and about 92 psf for PI ≥ 40, or 6.5 to 4.4 kPa)

suσ′p ≈ 0.11 + 0.0037 PI      suσ′v ≈ 0.22 · OCR0.8

Eq. D-6 (Skempton 1957; Mesri 1975 and Ladd 1991 SHANSEP form)

Eq. D-6 gives su of normally consolidated clay from its effective stress, which is often more reliable than the blow count in soft clay (N60 < 4), where one blow either way changes the consistency class.

sin φ′ ≈ 0.8 − 0.094 ln(PI)

Eq. D-7 (Bjerrum and Simons 1960; normally consolidated clays with PI about 10 to 80)

Table D-7: Drained Friction Angle of Fine-Grained Soils from Plasticity Index (Eq. D-7)
PI1020304060
φ′ (deg), peak, normally consolidated3631292725
Typical fully softened φ′ (deg)30–3426–3123–2820–2617–23
Typical residual φ′r (deg)25–3018–2613–2010–168–13

Source: Peak: Bjerrum and Simons (1960). Fully softened and residual: Stark and Eid (1994, 1997) and Stark, Choi and McCone (2005), ranges for effective normal stress of 1,000 to 4,000 psf; values depend on clay-size fraction and LL. Use fully softened strength for cut slopes and compacted clay fills, and residual strength where a slide surface has formed (Chapter 6.3, Section 6.3.6).

Limitations. The N–su relationship is unreliable in soft clay, in fissured or slickensided stiff clay (where it overestimates mass strength), and in clays with gravel. Do not use SPT-derived su for embankment stability on soft ground or for end-of-construction analysis; use vane, CPTu or laboratory strength. Correlations are for inorganic, unstructured soils; sensitive clays, cemented soils and residual soils (saprolite) can depart widely.

Follow-up testing: Pocket penetrometer and torvane on every Shelby tube and split-spoon sample (screening only); unconfined compression (ASTM D2166) or UU triaxial (ASTM D2850) on tube samples; field vane (ASTM D2573) or CPTu in soft clay; CU triaxial with pore pressure (ASTM D4767) for effective-stress parameters; ring shear (ASTM D6467) or torsional ring shear for residual strength in slide repairs.

D.4 Fine-Grained Soils: Moisture Content and Atterberg Limits

Moisture content and the Atterberg limits are cheap, fast and repeatable, and they are often more informative than the blow count in soft and medium fine-grained soils. Run them on every fine-grained sample.

Liquidity index

LI = w − PLLL − PL = w − PLPI

Eq. D-8

Table D-8: Consistency and Behavior from Liquidity Index
LIConditionTypical su of the remolded soil (psf, Eq. D-9)Engineering meaning
> 1.0Above the liquid limit< 35Very soft, sensitive or quick if structure is disturbed; normally consolidated or underconsolidated; expect large settlement
0.75–1.0Near the liquid limit35–110Soft; normally consolidated
0.5–0.75Upper plastic range110–360Medium stiff
0.25–0.5Mid plastic range360–1,100Stiff; often lightly overconsolidated
0–0.25Near the plastic limit1,100–3,550Very stiff; overconsolidated or desiccated
< 0Below the plastic limit> 3,550Hard; heavily overconsolidated, desiccated or cemented; check for swell
su,remolded (psf) ≈ 3,550 · e−4.6 LI

Eq. D-9 (after Wroth and Wood 1978: about 35 psf at the liquid limit and about 3,550 psf at the plastic limit)

Source: Liquidity index: ASTM D4318 definitions; behavior after Terzaghi, Peck and Mesri (1996) and Mitchell and Soga (2005). Eq. D-9 gives remolded strength; undisturbed strength of structured or overconsolidated clay can be several times higher.

Compressibility from moisture content and liquid limit

Cc ≈ 0.009 (LL − 10)     Cc ≈ 0.01 wn     Cr ≈ Cc/5 to Cc/10     Cα ≈ 0.04 Cc

Eq. D-10 (Terzaghi and Peck 1967; Koppula 1981; Mesri and Godlewski 1977; wn in %)

Table D-9: Typical Compressibility of Fine-Grained Soils by Moisture Content and Liquid Limit
USCS groupTypical LLTypical wn below water table (%)CcCrcv (ft2/day)Typical k (ft/day)
ML25–4515–350.10–0.300.01–0.050.5–200.003–3
CL25–5015–400.15–0.400.02–0.060.1–20.0003–0.03
MH50–8030–600.30–0.800.03–0.100.05–20.0003–0.03
CH50–10030–700.40–1.00.05–0.150.01–0.50.00003–0.003
OL / OH35–8040–1500.40–1.50.05–0.200.02–10.0003–0.03

Ranges compiled from Holtz, Kovacs and Sheahan (2011), Terzaghi, Peck and Mesri (1996) and NAVFAC DM-7.01 (1986).

Unit weight and void ratio from moisture content

Below the water table a fine-grained soil is saturated, so its moisture content fixes its void ratio and unit weight:

e = w Gs     γsat = Gs γw (1 + w)1 + w Gs     γd = Gs γw1 + w Gs

Eq. D-11 (S = 100%; γw = 62.4 pcf)

Table D-10: Saturated Unit Weight from Moisture Content (Gs = 2.70)
w (%)1520253040506080100
Void ratio, e0.410.540.680.811.081.351.622.162.70
γsat (pcf)1381311261211131081039691
γd (pcf)120109101938172645346

Computed from Eq. D-11. For each 0.1 change in Gs, γsat changes by about 1 to 3 pcf. Use Gs = 2.60 to 2.65 for soils with organic content and 2.75 to 2.80 for micaceous or iron-rich soils.

Limitations. The equations assume full saturation; above the water table, or in gassy organic soils, they overestimate unit weight. The Cc correlations carry an error of ±30% or more and do not apply to structured, sensitive or cemented clays, where Cc beyond the preconsolidation stress can be two to three times higher. Liquid limits run on oven-dried samples of organic or tropical soils can be much lower than on natural samples.

Follow-up testing: Natural moisture (ASTM D2216) on every sample; Atterberg limits (ASTM D4318, wet preparation) on each fine-grained stratum; specific gravity (ASTM D854) where unit weight governs; one-dimensional consolidation (ASTM D2435 or D4186) on tube samples under embankments and structures; organic content (ASTM D2974) where w or color suggest organics.

Supplemental reference · Carter & Bentley (2016), §6.5–6.6

Sensitivity, Undisturbed Strength and Friction Angle From Index Tests

Remolded strength. Skempton and Northey (1952) found that remolded strength plotted on a log scale is nearly linear in liquidity index, which gives su,r = n × 102(1 − LI) kPa, with n = 1 for 1 kPa (21 psf) at the liquid limit and 100 kPa (2,090 psf) at the plastic limit. In psf:

su,r ≈ 21 × 102(1 − LI)  (psf, n = 1)

Carter and Bentley found that n = 1 fits the measured strengths better than n = 2 but can still overestimate by a factor of 2 to 3. Eq. D-9 runs about 1.7 times higher than n = 1, so treat its values as an upper estimate of remolded strength.

Sensitivity from liquidity index. For clays of moderate sensitivity with liquidity index up to about 1.3, the Skempton and Northey trend is fitted by:

St ≈ 5.7 LI4 + 2 LI + 1

Undisturbed strength can then be estimated as St × su,r. The data behind this trend do not include the highly sensitive clays of eastern Canada and Scandinavia, which can be far more sensitive at the same LI.

Table D-S1. Sensitivity and estimated strength from liquidity index (after Skempton and Northey 1952, in Carter & Bentley 2016, Eqs. 6.18–6.19)
LI00.250.50.751.01.2
Sensitivity St1.01.52.44.38.715
Remolded su,r, n = 1 (psf)2,09066021066218
Remolded su,r, Eq. D-9 (psf)3,5501,1203601103614
Undisturbed estimate St × su,r (psf)2,090–3,5501,000–1,700490–840280–490180–310130–220

The European definitions of consistency (EC7) are based on liquidity index. Carter and Bentley converted them to strength ranges using these same relations, and the ranges are wide: very soft (LI > 0.75) under about 1,040 psf; soft (0.5–0.75) 520–1,460 psf; firm (0.25–0.5) 730–2,090 psf; stiff (0–0.25) 1,040–2,090 psf; very stiff (LI < 0) 1,460–2,920 psf. Their advice is that a hand vane or pocket penetrometer gives a far more reliable strength than any index correlation.

Strength from SPT, continuous form of Eq. D-5. Carter and Bentley fitted the Stroud and Butler (1975) curve for overconsolidated clays as su/N = 8,910/PI3 + 4.36 kPa, or in psf:

f1 = su/N60 ≈ 186,000 / PI3 + 91  (psf per blow; PI about 15 to 65)

This gives 146 psf at PI 15, 114 at PI 20, 98 at PI 30 and 92 at PI 60, consistent with the end points of Eq. D-5. Measured values scatter from about 10% above to 20% below the curve. The curve was derived only from overconsolidated deposits, and it should be used in normally consolidated clay only with caution, if at all.

Friction angle from plasticity index. Gibson (1953) related the drained friction angle of remolded clays, and the “true” angle of internal friction, to PI. Carter and Bentley fitted the curves as:

φ′ = 0.0058 PI1.73 − 0.32 PI + 36.2     φ′r = 0.084 PI1.4 − 0.75 PI + 31.9  (degrees)

Table D-S2. Friction angle from PI: Gibson curves compared with Eq. D-7 and Table D-7
PI101520304060
Gibson peak φ′, remolded (deg)33.332.030.828.726.823.9
Eq. D-7 peak φ′, normally consolidated (deg)35.733.131.228.727.024.5
Gibson “true” angle φ′r (deg)26.524.422.519.216.612.8
Table D-7 residual φ′r, ring shear (deg)25–30–18–2613–2010–168–13

The two peak relations agree within about 2° above PI 15. Gibson’s “true” angle is not a ring-shear residual strength: at PI 40 and above it plots at or above the top of the Table D-7 residual range. For a slide surface that has already formed, use the Table D-7 residual values or ring-shear tests.

For railroad work: On long track and embankment projects, moisture content and Atterberg limits are run on almost every sample, while strength tests are few. The relations above turn those index tests into a strength profile that shows where the soft, sensitive zones are, between the borings with vane or laboratory strength. Flag any sample with LI above about 0.75: it is likely to be sensitive, to lose much of its strength when disturbed by undercutting, piling or vibration, and to need field vane or CPTu strength before any stability or bearing design (Example D-2).

Source: Carter, M. and Bentley, S. P. (2016). Soil Properties and their Correlations, 2nd ed., §6.5.1–6.5.3 and §6.6, Eqs. 6.18–6.21, 6.27–6.28, Table 6.2, Figs. 6.4, 6.5, 6.10, 6.11. Summarized and paraphrased; equations converted to psf. Full reference under Author and Sources.

D.5 Organic Soils and Peat
Table D-11: Typical Properties of Organic Soils and Peat
PropertyOrganic silt / clay (OL, OH)Peat (PT)
Organic content (ASTM D2974, %)5–30> 50
N60 (blows/ft)0–50–2 (often weight of hammer)
Natural moisture, w (%)40–150200–1,500
Bulk unit weight, γ (pcf)85–10560–75
Specific gravity, Gs2.30–2.651.4–2.0
Undrained strength, su (psf)100–600100–400 (fibrous peat: use effective-stress methods)
Cc/(1 + e0)0.15–0.350.30–0.60
Cα/Cc0.04–0.060.05–0.07
Typical correlationCc ≈ 0.0115 wn (organic soils, wn in %)Cc ≈ 0.01 wn; secondary compression governs long-term settlement

Source: Mesri and Ajlouni (2007); Mesri, Stark, Ajlouni and Chen (1997); Edil and den Haan (1994); Holtz, Kovacs and Sheahan (2011).

Limitations. Peat and organic soils are highly variable over short distances; one boring is not representative of a reach. SPT blow counts are meaningless in peat. Strength and compressibility change with drainage and oxidation over time, and gas affects unit weight.

Follow-up testing: Continuous sampling or probing to define the extent and thickness; organic content and ash content (ASTM D2974); consolidation tests with long secondary-compression stages; field vane or CPTu for strength; settlement plates and piezometers during fill placement (Chapter 5.3).

D.6 Quick-Reference Table by Soil Type

One line per common soil type and condition. Use it for the first pass of a boring log; refine with the detailed tables above.

Table D-12: Quick-Reference Typical Values
Soil (USCS) and conditionN60w (%)LLγ (pcf)φ′ (deg)c′ or su (psf)Es (ksf)k (ft/day)Soaked CBR
GW/GP, dense30–50+3–8NP130–14038–4401,500–4,00030–3,00040–80
GM/GC, medium dense15–356–15NP–35125–13533–380–200800–2,0000.003–320–40
SW/SP, loose5–103–15NP95–11029–310200–5003–30010–20
SW/SP, medium dense11–303–12NP105–12031–360500–1,0003–30015–30
SM, medium dense11–308–20NP–30110–12529–340300–8000.03–310–20
SC, medium dense11–3010–2025–40115–12827–32c′ 0–200300–7000.0003–0.035–15
ML, loose / soft2–820–3525–45110–12027–31c′ 040–900.003–33–6
ML, medium dense / stiff9–2015–2525–45115–12530–34c′ 0–10090–1600.003–0.35–10
CL, soft2–430–4030–50105–11528–32su 250–50050–1500.0003–0.032–4
CL, stiff9–1518–2830–50120–12828–32su 1,000–2,000300–6000.0003–0.034–8
CL, very stiff to hard16–4012–2030–50125–13528–32su 2,000–6,000600–1,8000.0003–0.036–12
MH, firm4–1035–5550–8095–11026–31su 400–1,00040–1500.0003–0.032–6
CH, soft2–440–7050–9095–11024–29su 250–50040–1500.00003–0.0031–3
CH, stiff9–1525–4050–90110–12024–29su 1,000–2,000300–6000.00003–0.0032–5
OL/OH0–540–15035–8085–10522–30su 100–60010–600.0003–0.031–3
PT (peat)0–2200–1,500—60–75—su 100–400< 200.003–3< 1

φ′ for fine-grained soils is the peak drained value for normally consolidated material (Eq. D-7); use fully softened or residual values where Section D.3 calls for them. Es for clays is the undrained modulus. NP = non-plastic. CBR ranges after USACE and AASHTO subgrade practice; see Chapter 6.3.

Source: Compiled from Tables D-1 to D-11 and their sources; CBR from USACE EM 1110-3-138 and the Unified Facilities Criteria for pavement subgrades (UFC 3-250-01).

D.7 Where the Values Came From and Their Limitations
Table D-13: Sources of the Typical Values
TopicPrimary sourcesBasis of the data
SPT corrections and density termsTerzaghi and Peck (1948, 1967); Skempton (1986); Youd et al. (2001)Field and laboratory comparisons, mostly in clean quartz sands
Friction angle of sands from NPeck, Hanson and Thornburn (1974); Schmertmann (1975); Kulhawy and Mayne (1990); Hatanaka and Uchida (1996)Back-calculation and triaxial tests on reconstituted and frozen samples
Unit weights and moistureNAVFAC DM-7.01 (1986); phase relationships (Eq. D-11)Compilations of laboratory data from U.S. projects
Consistency and su of clays from NTerzaghi and Peck (1967); Stroud (1974)Comparison of SPT with unconfined and triaxial tests; Stroud's data are from UK overconsolidated clays
su from stress history and PISkempton (1957); Ladd and Foott (1974); Mesri (1975); Ladd (1991)Field vane and laboratory tests on normally and lightly overconsolidated clays
Friction angle of clays from PIBjerrum and Simons (1960); Stark and Eid (1994, 1997)Triaxial and ring shear tests
Liquidity index and remolded strengthWroth and Wood (1978); Mitchell and Soga (2005)Fall-cone and vane tests on remolded soils
CompressibilityTerzaghi and Peck (1967); Hough (1957); Koppula (1981); Mesri and Godlewski (1977)Oedometer test databases
Modulus and subgrade reactionBowles (1996); Duncan and Buchignani (1976); Terzaghi (1955)Plate load, pressuremeter and laboratory data
Organic soils and peatMesri and Ajlouni (2007); Edil and den Haan (1994)Field and oedometer data from peat and organic deposits
PermeabilityUSACE EM 1110-2-1901; Holtz, Kovacs and Sheahan (2011)Laboratory and field test compilations

General limitations

  • Typical, not site-specific. The ranges describe common soils. Any one site can fall outside them, and the ranges overlap so that a single number cannot be read with precision.
  • Correlations carry large scatter. Most N-based correlations predict the measured property within about ±30% to ±50% at best; the su–N relationship scatters by a factor of two.
  • Developed on specific soils. Most correlations come from uncemented quartz sands and inorganic, unstructured clays of temperate regions. They do not apply reliably to residual soils and saprolite, cemented or calcareous soils, sensitive or quick clays, fissured clays, collapsible loess, expansive clays, glacial till with cobbles, or fill.
  • Field procedure matters. Hammer type, borehole stabilization and sampler condition change N by 50% or more. Uncorrected or poorly logged blow counts cannot be converted reliably.
  • Drainage and loading conditions. The tables give one value per parameter. Design needs the parameter for the right drainage state (drained, undrained, fully softened, residual) and the right strain level and loading rate.
  • Not for final design of critical elements. Do not use these values alone for final design of embankments on soft ground, slope repairs, retaining walls, bridge foundations or liquefaction mitigation.
  • No client data. The values are from published sources only and contain no client- or project-specific data.
D.8 Follow-Up Testing to Replace Typical Values

List every Appendix D value used in a calculation, then schedule the test that replaces it. The table is ordered from the cheapest screening tests to the definitive tests.

Table D-14: Recommended Follow-Up Testing
Parameter estimated from Appendix DScreening test (every boring)Definitive testWhen the definitive test is needed
Soil classificationVisual-manual (ASTM D2488)Grain size (D6913, D7928) and Atterberg limits (D4318); classification (D2487)Always, for each stratum
Moisture content, unit weightMoisture content (D2216)Unit weight of tube samples (D7263); specific gravity (D854)Settlement, stability and earth pressure analyses
Relative density, φ′ of sandSPT with energy measurement (D1586, D4633)CPTu (D5778); direct shear (D3080) or CD triaxial (D7181) on reconstituted samplesFoundations, walls, liquefaction checks
su of clayPocket penetrometer, torvaneUU triaxial (D2850), unconfined compression (D2166), field vane (D2573), CPTuEmbankments on soft ground; end-of-construction stability; bearing on clay
Effective-stress strength of clayAtterberg limits (Eq. D-7)CU triaxial with pore pressure (D4767); direct shear (D3080)Long-term slope and wall design
Fully softened and residual strengthAtterberg limits and clay fractionRing shear (D6467, D7608)Cut slopes in clay, slide repairs
Compressibility and stress historyMoisture, LL, LIConsolidation (D2435, D4186); CPTu with dissipationFills, structures and embankments on fine-grained soils
Modulus and subgrade reactionSPT, DCP (D6951)Plate load test (D1196), pressuremeter (D4719), seismic methods (MASW)Track modulus, slabs, crane rails, machine foundations
PermeabilityGrain size (Hazen-type estimates)Slug or pumping tests; laboratory permeability (D5084, D2434)Dewatering, seepage, drainage design
Subgrade support (CBR, Mr)DCP (D6951)Laboratory CBR (D1883), resilient modulus (AASHTO T 307)Track subgrade and pavement design (Chapter 7.3)
Organic soilsColor, odor, moistureOrganic content (D2974); long-term consolidationAny fill or structure over organic soil

See Chapter 5.2, Section 5.2.3 for test procedures and Chapter 5.1 for in situ testing.

D.9 Worked Example
The example is laid out as Given, Required, Equations, a flow chart of the steps with a spot check at each, and the Solution.
Example D-1: Preliminary Parameters From a Boring Log

A boring for a culvert replacement under a main-line embankment, with blow counts and index tests only. The appendix tables and correlations give preliminary design parameters, and a stress-history check tests whether they make sense together before anything is designed.

Given

VariableValueDescription
0 to 8 ftSP-SM; N = 12 at 6 ft; w = 9%Water table at 8 ft
8 to 20 ftCL; N = 4 to 6; w = 31%; LL 38; PL 19
Below 20 ftSP; N = 38
HammerAutomatic, Em = 85%; CB = CS = 1.0
CR0.75 (5 to 10 ft rods); 0.85 (10 to 15 ft)

Required

  • N60 for the sand and clay
  • Preliminary φ′, su, Cc, and a check against stress history

Equations

  1. Eq. D-1: N60 = N(Em/60)CBCSCR; (N1)60 = CNN60
  2. Eq. D-2: φ′ = 27.1 + 0.3(N1)60 − 0.00054(N1)60² — Peck et al.
  3. Eq. D-5: su = f1N60 — Stroud; f1 ≈ 129 psf at PI 19
  4. Eq. D-8: LI = (w − PL)/(LL − PL)
  5. Eq. D-10: Cc = 0.009(LL − 10) or 0.01w
  6. Eq. D-6: su,NC ≈ 0.22σ′v — normally consolidated check

Steps

Step 1 · N60 (Eq. D-1)
Sand: 12 × 85/60 × 0.75; clay: 5 × 85/60 × 0.85
13 and 6
↓
Step 2 · Sand (Eq. D-2)
σ′v at 6 ft ≈ 670 psf, CN = 1.78, use 1.7; (N1)60 = 1.7 × 13 = 22; 27.1 + 6.6 − 0.26 = 33.4°; SM adjustment about −2° (Table D-5)
φ′ ≈ 31°; medium dense; γ ≈ 110 to 115 pcf
↓
Step 3 · Clay strength (Eq. D-5, D-8)
f1 = 6.5 − 4(0.084) = 6.16 kPa = 129 psf; 129 × 6 = 770 psf; LI = 12/19 = 0.63
Medium stiff by both
↓
Step 4 · Cc (Eq. D-10)
0.009 × 28; 0.01 × 31
0.25 to 0.31; use 0.28
↓
Step 5 · Stress-history check (Eq. D-6)
σ′v at 14 ft = 8(115) + 6(57.6) = 1,266 psf; 0.22 × 1,266
280 psf, about one-third of 770 psf
Spot check: su/σ′v = 0.61 implies OCR of about 3.5 by Eq. D-6 (a desiccated crust or old fill), or blow counts that overstate the strength.
↓
Solution
Sand φ′ = 31°; clay su = 500 psf; Cc = 0.28.

Solution

Preliminary values: sand φ′ = 31°; clay su = 500 psf (flagged); Cc = 0.28.

The N-based strength is more than twice what a normally consolidated clay at this depth would have, so 500 psf is used and the discrepancy is flagged rather than resolved by choosing the higher number. Record the basis in the calculation package (Tables D-3, D-4, D-5, D-8 and D-10; Eqs. D-5 to D-10) and replace the values with UU triaxial, consolidation and grain-size results before final design.

Example D-2: Strength Profile of a Soft Clay From Index Tests and Blow Counts

A Class I railroad located in Indiana plans to raise a main-line embankment 3 ft over a lean clay foundation. The borings have blow counts and index tests but no strength tests yet. At mid-depth of the clay, a sample has w = 32%, LL = 42 and PL = 20, with N60 = 6. The engineer must estimate the undrained strength from both the index tests and the blow count, judge how sensitive the clay is, estimate a drained friction angle, and decide what strength testing to order before the stability analysis.

3-ft raiseexisting embankment lean clay (CL) sand w = 32%, LL = 42, PL = 20N60 = 6 su = ? St = ? φ′ = ? Givenw = 32%; LL = 42; PL = 20N60 = 6 at the same depthLean clay (CL), no strength tests RequiredLI and sensitivitysu from index tests (range)su from N60 (Stroud)φ′ and true angle from PITesting to order Black = given; red = required
Given and required for Example D-2.

Given

VariableValueDescription
w32%Natural moisture content at mid-depth of the clay
LL, PL42, 20Atterberg limits; PI = 22
N606Energy-corrected blow count at the same depth

Required

  • (a) Liquidity index and sensitivity
  • (b) Remolded and undisturbed strength from the index tests
  • (c) Strength from the blow count
  • (d) Peak and “true” friction angles from PI
  • (e) What testing to order

Equations

  1. Eq. 1: LI = (w − PL)/PI — Eq. D-8
  2. Eq. 2: St = 5.7 LI4 + 2 LI + 1
  3. Eq. 3: su,r = 21 × 102(1 − LI) psf, or 3,550 e−4.6 LI psf (Eq. D-9)
  4. Eq. 4: su = f1 N60, f1 = 186,000/PI3 + 91 psf
  5. Eq. 5: φ′ = 0.0058 PI1.73 − 0.32 PI + 36.2; φ′r = 0.084 PI1.4 − 0.75 PI + 31.9

Steps

Step 1 · (a) LI and St (Eqs. 1, 2)
LI = (32 − 20)/22 = 0.545; St = 5.7 × 0.088 + 2 × 0.545 + 1
LI = 0.55; St ≈ 2.6 (low to medium sensitivity)
↓
Step 2 · (b) Remolded strength (Eq. 3)
21 × 100.91 = 170 psf; Eq. D-9: 3,550 × e−2.51 = 290 psf
su,r ≈ 170 to 290 psf
↓
Step 3 · (b) Undisturbed strength
2.6 × 170 = 440 psf; 2.6 × 290 = 750 psf
su ≈ 440 to 750 psf from the index tests
Spot check: Table D-S1 at LI = 0.5 gives 490–840 psf; LI 0.55 is slightly wetter, so slightly lower.
↓
Step 4 · (c) Strength from N60 (Eq. 4)
f1 = 186,000/223 + 91 = 17 + 91 = 108 psf per blow; 108 × 6
su ≈ 650 psf
Spot check: Table D-6 for N60 5–8 (medium stiff) gives 500–1,000 psf.
↓
Step 5 · (d) Friction angles (Eq. 5)
221.73 = 210; 221.4 = 75.8
φ′ ≈ 30° (Eq. D-7 gives 31°); φ′r ≈ 22°
↓
Solution
su about 440 to 750 psf, St about 2.6, φ′ about 30°: preliminary only.

Solution

(a) LI = 0.55 and St ≈ 2.6. (b) Remolded strength 170 to 290 psf; undisturbed strength 440 to 750 psf. (c) su ≈ 650 psf from N60. (d) φ′ ≈ 30° and a “true” angle of about 22°. (e) Order field vane or CPTu soundings and UU triaxial tests before the stability analysis.

The three estimates agree on a medium-stiff clay of about 450 to 750 psf, so a preliminary short-term stability check of the 3-ft raise can use the low end, about 450 psf. The agreement is reassuring but not proof. The Stroud factor was fitted to overconsolidated clays, and the index relations can overestimate by a factor of two or more. With a sensitivity of about 2.6, the clay keeps most of its strength under construction disturbance, but undercutting or sheet-pile driving at the toe will still reduce it locally. For the long-term case, use about 30° with c′ = 0 for intact clay; the 22° true angle is not a residual strength for an existing slide surface. Field vane or CPTu soundings at the raise, corrected for plasticity (Bjerrum’s factor, Chapter 5.1), will set the design strength.

D.10 Cross-References
TopicRefer To
SPT procedure and correctionsChapter 4.1, Section 4.1.3
In situ testing (CPTu, vane, pressuremeter, MASW)Chapter 5.1
Soil classification (USCS, AASHTO)Chapter 2.2, Section 2.2.4
Laboratory test methodsChapter 5.2, Section 5.2.3
Consolidation settlementChapter 6.2, Section 6.2.4
Residual and fully softened strengthChapter 6.3, Section 6.3.6
Liquefaction of sands and siltsChapter 6.5, Section 6.5.5
Pavement and track subgrade valuesChapter 7.3, Section 7.3.2
Silts: typical values and behaviorChapter 2.4
Analytical equationsAppendix F
D.11 SPT Corrections and Property Correlations Calculator

Carter and Bentley's Soil Properties and their Correlations and Look's Handbook of Geotechnical Investigation and Design Tables collect the correlations used when the only data are blow counts and index tests. The calculator applies the standard corrections and then the most widely used correlations, showing more than one where they disagree, so the user sees the spread rather than a single number. Section D.8 explains which follow-up tests replace these values for design.

D.11.1 Corrections and correlations

Equation D-1. Corrected blow counts

N60 = N (ER/60) CB CS CR;  (N1)60 = CN N60,  CN = (Pa/σ'v)0.5 ≤ 1.7
Table D-15: Correlations used by the calculator
PropertyCorrelationSoil
Relative densityDr ≈ [(N1)60/60]0.5 (Skempton)Sand
Friction angleφ' = √(15.4(N1)60) + 20 (Hatanaka and Uchida, GEC 5 form); φ' = 27.1 + 0.3(N1)60 − 0.00054(N1)60² (Peck et al.)Sand
Drained modulusEs/Pa ≈ 10 N60 clean NC sand (5 silty, 15 OC)Sand
Undrained strengthsu = f1N60, f1 about 135 psf (6.5 kPa) at PI 15 to 92 psf (4.4 kPa) at PI ≥ 40 (Stroud)Clay
Compression index0.009(LL − 10); 0.01(LL − 13); 0.012 wn (EM 1110-1-1904)Clay

D.11.2 Worked examples

Table D-16: Sand and clay samples from a railroad boring (calculator output)
SampleDataResults
Sand at 12 ft, water at 6 ftN = 14, ER 80%N60 15.9; (N1)60 22.1; medium dense; φ' 33.5 deg to 38.4 deg; Es about 336 ksf
Clay at 12 ft, PI 25, LL 45, w 30%N = 9, ER 80%N60 10.2; stiff; su about 1,206 psf; Cc 0.32 to 0.36

Open the SPT correlations calculator →
SPT energy, rod, borehole, sampler and overburden corrections, then relative density, friction angle, modulus, undrained strength and compression index estimates.

D.11.3 Sources in the library

These documents are in the reference library. The method summaries above are paraphrased; equations are standard forms.

Author and Sources

Author: Daniel P. Colwell. This appendix was compiled by Daniel P. Colwell for Railway Ground Hazard Risk Management from the published sources below; credit for that material belongs to their authors and publishers. It contains no client- or project-specific data.

Sources

  • Bjerrum, L. and Simons, N. E. (1960). “Comparison of Shear Strength Characteristics of Normally Consolidated Clays.” Proc. ASCE Research Conf. on Shear Strength of Cohesive SoilsFind source ↗
  • Bowles, J. E. (1996). Foundation Analysis and Design, 5th ed. McGraw-HillFind source ↗
  • Duncan, J. M. and Buchignani, A. L. (1976). An Engineering Manual for Settlement Studies. University of California, BerkeleyFind source ↗
  • Edil, T. B. and den Haan, E. J. (1994). “Settlement of Peats and Organic Soils.” ASCE GSP 40Find source ↗
  • Hatanaka, M. and Uchida, A. (1996). “Empirical Correlation between Penetration Resistance and Internal Friction Angle of Sandy Soils.” Soils and Foundations, 36(4)Find source ↗
  • Holtz, R. D., Kovacs, W. D. and Sheahan, T. C. (2011). An Introduction to Geotechnical Engineering, 2nd ed. PearsonFind source ↗
  • Hough, B. K. (1957). Basic Soils Engineering. Ronald PressFind source ↗
  • Idriss, I. M. and Boulanger, R. W. (2008). Soil Liquefaction During Earthquakes. EERI MNO-12Find source ↗
  • Koppula, S. D. (1981). “Statistical Estimation of Compression Index.” Geotechnical Testing Journal, 4(2)Find source ↗
  • Kulhawy, F. H. and Mayne, P. W. (1990). Manual on Estimating Soil Properties for Foundation Design. EPRI EL-6800Find source ↗
  • Ladd, C. C. (1991). “Stability Evaluation during Staged Construction.” J. Geotech. Eng., 117(4); Ladd, C. C. and Foott, R. (1974). J. Geotech. Eng. Div., 100(GT7)Find source ↗
  • Liao, S. S. C. and Whitman, R. V. (1986). “Overburden Correction Factors for SPT in Sand.” J. Geotech. Eng., 112(3)Find source ↗
  • Mesri, G. (1975). “Discussion of New Design Procedure for Stability of Soft Clays.” J. Geotech. Eng. Div., 101(GT4); Mesri, G. and Godlewski, P. M. (1977). “Time and Stress-Compressibility Interrelationship.” 103(GT5)Find source ↗
  • Mesri, G. and Ajlouni, M. (2007). “Engineering Properties of Fibrous Peats.” J. Geotech. Geoenviron. Eng., 133(7)Find source ↗
  • Mesri, G., Stark, T. D., Ajlouni, M. A. and Chen, C. S. (1997). “Secondary Compression of Peat with or without Surcharging.” J. Geotech. Geoenviron. Eng., 123(5)Find source ↗
  • Mitchell, J. K. and Soga, K. (2005). Fundamentals of Soil Behavior, 3rd ed. WileyFind source ↗
  • NAVFAC (1986). Design Manual 7.01: Soil Mechanics. Naval Facilities Engineering CommandFind source ↗
  • Peck, R. B., Hanson, W. E. and Thornburn, T. H. (1974). Foundation Engineering, 2nd ed. Wiley; Wolff, T. F. (1989). Pile capacity prediction using parameter functions. ASCE GSP 23Find source ↗
  • Schmertmann, J. H. (1975). “Measurement of In Situ Shear Strength.” Proc. ASCE Specialty Conf. on In Situ Measurement of Soil PropertiesFind source ↗
  • Skempton, A. W. (1957). “The Planning and Design of the New Hong Kong Airport.” Proc. ICE, 7; Skempton, A. W. (1986). “Standard Penetration Test Procedures and the Effects in Sands of Overburden Pressure, Relative Density, Particle Size, Ageing and Overconsolidation.” Géotechnique, 36(3)Find source ↗
  • Stark, T. D. and Eid, H. T. (1994, 1997). Drained residual and fully softened strengths of clays. J. Geotech. Eng., 120(5); J. Geotech. Geoenviron. Eng., 123(4); Stark, T. D., Choi, H. and McCone, S. (2005). 131(5)Find source ↗
  • Stroud, M. A. (1974). “The Standard Penetration Test in Insensitive Clays and Soft Rocks.” Proc. European Symposium on Penetration TestingFind source ↗
  • Terzaghi, K. (1955). “Evaluation of Coefficients of Subgrade Reaction.” Géotechnique, 5(4)Find source ↗
  • Terzaghi, K. and Peck, R. B. (1948, 1967). Soil Mechanics in Engineering Practice. Wiley; Terzaghi, Peck and Mesri (1996), 3rd ed.Find source ↗
  • USACE EM 1110-1-1904, Settlement Analysis; EM 1110-2-1901, Seepage Analysis and Control for Dams; EM 1110-3-138, Pavement Criteria for Seasonal Frost Conditions; UFC 3-250-01, Pavement Design for Roads and Parking AreasOfficial page ↗Library entry
  • Wroth, C. P. and Wood, D. M. (1978). “The Correlation of Index Properties with Some Basic Engineering Properties of Soils.” Can. Geotech. J., 15(2)Find source ↗
  • Youd, T. L. et al. (2001). J. Geotech. Geoenviron. Eng., 127(10)Find source ↗
  • ASTM D1586, D2166, D2216, D2435, D2487, D2488, D2573, D2850, D2974, D3080, D4186, D4318, D4633 (withdrawn 2025), D4767, D5778, D6467, D6913, D6951, D7263, D7928; AASHTO T 307Official page ↗
← Previous · Appendices Appendices
Next · Appendices → Appendix F — Analytical Equations