D.2 Coarse-Grained Soils (Gravels and Sands)

Starting values for each soil type, read from the three numbers every boring gives: the SPT blow count, the natural moisture content and the liquid limit. Each table names where its values came from, what they cannot be used for, and which tests should replace them.
Author: Daniel P. Colwell
D.2 Coarse-Grained Soils (Gravels and Sands)

For gravels and sands, the blow count controls the estimate. Moisture content has little effect on the strength of clean coarse soils, but it is needed for unit weight above the water table.

Table D-4: Typical Properties of Clean Sands (SW, SP) by Density
PropertyVery looseLooseMedium denseDenseVery dense
N60 (blows/ft)0–45–1011–3031–50> 50
Friction angle, φ′ (deg)26–2929–3131–3636–4141–45
Moist unit weight, γ (pcf)90–10095–110105–120115–130120–135
Saturated unit weight, γsat (pcf)110–118115–122120–128125–135130–140
Natural moisture above water table (%)3–153–153–123–103–10
Young's modulus, Es (ksf)100–200200–500500–1,0001,000–1,7001,700–2,500
Coefficient of subgrade reaction, ks, 1-ft plate, above / below water table (pci)< 45 / < 3045 / 30150 / 95580 / 350> 580 / > 350

Source: φ′: Peck, Hanson and Thornburn (1974) and NAVFAC DM-7.01 (1986). Unit weights: NAVFAC DM-7.01 and Holtz, Kovacs and Sheahan (2011). Es: Bowles (1996). ks: Terzaghi (1955) for a 1-ft square plate (his recommended 40, 130 and 500 tons/ft³ for loose, medium dense and dense sand above the water table and 25, 80 and 300 tons/ft³ submerged, converted to pci); scale to the loaded width before use. These are vertical plate values, not the p-y modulus constants used for laterally loaded piles.

Table D-5: Adjustments for Other Coarse-Grained Groups
USCS groupφ′ adjustment to Table D-4Unit weight adjustmentPermeability, k (ft/day)Notes
GW, GP (gravels)+2° to +4°+5 to +10 pcf300–3,000 (GP), 30–300 (GW)N inflated by cobbles; discount refusal blows
GM, GC (silty, clayey gravel)0° to +2°+5 pcf0.003–3Drainage and frost behavior controlled by fines
SW, SP (clean sand)Table D-4 as given—3–300 (SP fine sand 3–30)—
SM (silty sand)−2° to −4°−0 to −5 pcf0.03–3See Chapter 2.4 for silt-controlled behavior; liquefiable when loose and saturated
SC (clayey sand)−3° to −6°; c′ = 0–200 psf—0.0003–0.03Moisture-sensitive; use D.3 for strength if fines are plastic and exceed about 30%

Source: Holtz, Kovacs and Sheahan (2011); NAVFAC DM-7.01 (1986); USACE EM 1110-2-1901 (permeability).

Correlations

φ′ ≈ 27.1 + 0.3 (N1)60 − 0.00054 (N1)602

Eq. D-2 (Peck, Hanson and Thornburn 1974, as fitted by Wolff 1989)

φ′ ≈ tan−1[N60 / (12.2 + 20.3 σ′v/pa)]0.34     pa = 2,117 psf

Eq. D-3 (Kulhawy and Mayne 1990; Schmertmann 1975)

Eq. D-2 uses the overburden-corrected blow count, as the Peck, Hanson and Thornburn chart does; it gives about 28° at (N1)60 = 4, 30° at 10, 33° at 20, 36° at 30 and 38° at 40. Eq. D-3 uses N60 and σ′v directly and is a useful cross-check below about 20 ft. Hatanaka and Uchida (1996), in the FHWA GEC 5 form for 60% energy, φ′ = √[15.4 (N1)60] + 20, gives higher values (about 37.5° at (N1)60 = 20; the original √(20 N1) + 20 is for Japanese SPT energy) and is calibrated on high-quality frozen samples of clean sand; cap it at 45° and do not use it for silty sands.

Es (ksf) ≈ 10 (N60 + 15)   (sand)      Es (ksf) ≈ 6.3 (N60 + 6)   (silty or clayey sand)

Eq. D-4 (after Bowles 1996, converted from kPa)

Eq. D-4 and the Es/pa ≈ 10 N60 form used by the calculator (Kulhawy and Mayne 1990) give values near the lower end of the Table D-4 ranges for medium dense and denser sand; the spread is typical of modulus correlations, and the lower value is the safer one for settlement.

Limitations. Values are for uncemented, normally consolidated, predominantly quartz sands. Cemented, calcareous, micaceous or crushable sands, and overconsolidated or aged deposits, can fall well outside these ranges. φ′ correlations do not apply to gravel with cobbles, where blow counts are unreliable. The moduli are for static loading at moderate strain; track and machine-foundation problems at small strain need shear-wave velocity (Chapter 5.1, Section 5.1.6).

Follow-up testing: Grain-size analysis (ASTM D6913) on every sample; energy measurement of the SPT hammer (ASTM D4633, withdrawn 2025); direct shear (ASTM D3080) on reconstituted samples at field density; CPTu soundings for continuous density profile; field permeability tests where drainage or dewatering governs.