3.5.10 Drainage Area, Peak Flow and Culvert Headwater

Water is the most common trigger of track failure, and the culverts through an embankment set how much water it holds back. The site-conditions review should therefore establish the drainage area of each crossing, a design flow, and whether the existing opening is adequate. AREMA Chapter 1, Parts 3 and 4, give the rational method for small basins and the culvert design criteria; railroad culvert guidelines add a 100-year design storm, E80 loading, and a 36 in. minimum pipe.

3.5.10.1 Method and criteria

Equation 3.5-1. Peak flow and time of concentration

Q = C i A   Kirpich: tc = 0.0078 L0.77/S0.385   Kerby: tc = 0.83 (N L/S0.5)0.467

Q in cfs, i in in./hr for a duration equal to tc, A in acres; tc in minutes, L in ft, S in ft/ft. Use the rational method with caution above about 300 acres (Kirpich is intended for agricultural basins under 200 acres).

Table 3.5-7. Rural runoff coefficients (AREMA Table 1-3-1)
Vegetation and slopeOpen sandy loamClay and silt loamTight clay
Woodland: flat / rolling / hilly0.10 / 0.25 / 0.300.30 / 0.35 / 0.500.40 / 0.50 / 0.60
Pasture: flat / rolling / hilly0.10 / 0.16 / 0.220.30 / 0.36 / 0.420.40 / 0.55 / 0.60
Cultivated: flat / rolling / hilly0.30 / 0.40 / 0.520.50 / 0.60 / 0.720.60 / 0.70 / 0.82

Flat 0 to 5%, rolling 5 to 10%, hilly 10 to 30% slope. Urban values are in AREMA Table 1-3-2; a railroad yard is 0.20 to 0.35.

Table 3.5-8. AREMA culvert design criteria
FloodCriterion
25-yearDischarged without static head at the entrance (HW/D ≤ 1.0)
100-yearHeadwater no higher than the available head, 2 ft below base of rail, or 1.5 times the diameter, whichever is least

The calculator computes inlet-control headwater with the FHWA HDS-5 equations that underlie the charts AREMA cites. Outlet control (barrel friction and tailwater) should also be checked for long or flat culverts.

3.5.10.2 Worked example: 60-acre pasture basin

Table 3.5-9. C = 0.36, L = 3,000 ft, S = 0.015; i25 = 4.0 and i100 = 5.2 in./hr (calculator output)
ResultValue
Time of concentration (Kirpich)18.7 min
Q25 / Q10086 cfs / 112 cfs
60 in. corrugated metal pipe with headwall: HW/D at Q250.76
Headwater at Q100 (limit 7.5 ft)4.5 ft
Adequate (inlet control)yes

Rainfall intensities are illustrative; read them from the local intensity-duration-frequency curve at tc.

Open the culvert hydrology calculator →
Rational-method peak flows with Kirpich or Kerby time of concentration, and inlet-control headwater checked against the AREMA criteria.

3.5.10.3 Sources in the library

These documents are in the reference library. The summaries above are paraphrased; equations and tabulated limits are standard or published values. Individual railroads are not named.

Supplemental reference · Goswami (2015), Ch. 304

Runoff from Larger Basins: the NRCS Curve Number and Unit Hydrograph

The rational method in this section suits small basins. For larger or mixed-use basins, and wherever the runoff volume or the shape of the flood matters, the NRCS (formerly SCS) methods are used.

S = 1000 / CN − 10    Ia = 0.2 S    Q = (P − Ia)2 / (P − Ia + S) for P > Ia

  • CN = curve number (about 30 to 98) from land use, cover condition and hydrologic soil group A to D; S = potential maximum retention (in.); Ia = initial abstraction (in.); P = storm rainfall (in.); Q = runoff depth (in.).
  • TR-55 peak discharge: qp = qu Am Q Fp, with qu = unit peak discharge (csm/in.) from the time of concentration, Ia/P and the rainfall distribution type; Am = drainage area (mi²); Fp = adjustment for ponds and swamps.
  • NRCS synthetic unit hydrograph: qp = 484 A Q / Tp (cfs), with A in mi², Q = 1 in., and time to peak Tp = D/2 + 0.6 tc (hr) for a rainfall excess of duration D. Unit hydrographs can be lagged and summed to build the flood hydrograph for a design storm.
  • Time of concentration can be built up from sheet flow, shallow concentrated flow and channel flow segments, rather than one empirical formula.

For railroad work: Use the curve number method where a culvert or bridge drains more than a few hundred acres, where the basin is urbanizing (raise CN for future development, since railroad culverts outlast the land use around them), or where water ponds against the embankment and the volume matters for seepage and stability during the flood (Chapter 2.8, Chapter 6.3). A change in CN upstream is one of the triggers worth recording in the desktop study and the live rating (Chapter 3.8).

Source: Goswami, I. (2015). Civil Engineering All-In-One PE Exam Guide: Breadth and Depth, 3rd ed. New York: McGraw-Hill Education, Chapter 304, Hydrology.

Larger basins, ponding and snowmelt: flood hydrographs, routing behind embankments and flood frequency are in Section 3.5.12; snowmelt and rain on snow in Section 3.5.13.