List the structures and utilities that the work must avoid or that the design must account for: bridges and culverts (type, size, material, condition), retaining walls, signal masts and cabinets, buried cables and conduits, sewers and storm drains, overhead power. Take them from the railroad valuation maps and confirm them in the field.
| Item | Record |
|---|---|
| Culverts | Location (station), size, material, length, inlet and outlet condition, flow |
| Bridges and walls | Location, type, foundation if known, condition |
| Signals and communications | Masts, cabinets, foundations, conduits at grade; keep borings clear |
| Sewers and storm drains | Size and location from valuation maps and city atlases; relation to ditches and odors |
| Overhead lines | Clearance for the drill mast |