Foundation elements are ultimately judged by their effect on track geometry. FRA 49 CFR 213.63 sets surface (profile, cross-level and warp) limits by track class. A foundation that causes geometry to exceed those limits between normal maintenance cycles is not performing, whatever its calculated factor of safety.
| Criterion | Common Target (confirm with client) | Where Evaluated |
|---|---|---|
| Static slope stability, embankments and cuts | FS ≥ 1.5 with design train surcharge | Chapter 6.3 |
| Subgrade and foundation bearing under cyclic load | FS ≥ 3.0 on undrained bearing (Chapter 2.3 method) | Chapters 2.3, 6.1 |
| Post-construction settlement of new fill | Limited so that geometry remains correctable by routine surfacing; client-specific | Chapter 6.2 |
| Differential settlement at transitions | Minimized; evaluate over the transition length rather than as a single number | Chapters 2.3, 6.2 |
| Culvert and structure foundations | Per AREMA MRE Ch. 8 and the client's structure standards | Chapter 6.1 |
European practice sets three tiers of geometry limits: intervention values that trigger scheduled maintenance, acceptance values allowed to remain after maintenance, and emergency values that require an immediate speed restriction. FRA Track Safety Standards (49 CFR Part 213) and client standards govern in North America; the European figures are given to show how tight track-support performance has to be.
| Longitudinal defect LD (in.) | Horizontal defect HD (in.) | Maximum speed (mph) |
|---|---|---|
| ≥ 0.71 | ≥ 0.59 | 87 |
| ≥ 0.79 | ≥ 0.67 | 75 |
| ≥ 0.91 | ≥ 0.75 | 62 |
| ≥ 1 | ≥ 0.87 | 50 |
| ≥ 1.1 | ≥ 1 | 37 |
| ≥ 1.2 | ≥ 1.1 | 25 |

33-ft measurement base. LD = surface (profile), HD = alignment.
| Speed (mph) | Minimum gauge deviation (in.) | Maximum gauge deviation (in.) |
|---|---|---|
| V ≤ 50 | −0.35 | +1.4 |
| 50 < V ≤ 75 | −0.35 | +1.4 |
| 75 < V ≤ 99 | −0.31 | +1.4 |
| 99 < V ≤ 143 | −0.28 | +1.1 |
| V > 143 | −0.2 | +1.1 |
The European interoperability specifications also limit twist to 0.084 in./ft for speeds up to 124 mph and 0.06 in./ft above, adjusted for measurement base length (Figure 2.1-12), and limit the difference between nominal and actual cant to ±0.79 in..

After Profillidis (2014), §16.6, Tables 16.2, 16.4, 16.5, Fig. 16.7. Full reference under Supplemental References.