↑ Parent Menu⌂ Main Menu
← Chapter 7.4 Earthworks Asset Management and Remedial Design
GHRM
Railway Ground Hazard Risk Management · 7.0 · Design
Sections · open a dropdown to go to a section or subsection

7.4.5 Remedial Options

Treating the cuts and embankments of a railroad as an asset portfolio: inventory, condition, deterioration, prioritization and the choice of remedial works.
Author: Daniel P. Colwell
7.4.5 Remedial Options
Table 7.4-3. Remedial measures for earthworks
CategoryMeasuresNotes
DrainageDitch cleaning and lining, culvert repair and upsizing, horizontal drains, trench drains, surface water diversionUsually the most cost-effective; clean ditches without undercutting the toe
GeometrySlope flattening, unloading the crest, toe berms and buttressesNeeds right-of-way; berms must sit on competent ground
StructuralSoldier pile and lagging walls, drilled shaft walls, sheet piles, anchored wallsRailroads favor driven or drilled soldier pile walls for stabilization (Chapter 7.1)
ReinforcementSoil nails, rock bolts, reinforced slopesCheck corrosion where ground chemistry is aggressive (Chapter 2.12)
Ground improvementGrouting, deep mixing, lime injection, aggregate columnsSee Chapter 7.2
Rock slopeScaling, trim blasting, mesh and drapes, rockfall barriers, catch ditches, slide fencesDetectors provide warning, not prevention
Erosion and scourRiprap, gabions, articulated mats, vegetation, channel trainingSize for design flood; protect toe below scour depth
OperationalMonitoring, speed restrictions, slide detection, inspection after stormsThe observational approach (Chapter 5.5)
Trench excavation and placement of Electro-Kinetic Geosynthetic (EKG) electrodes
Photo 7.4.5-1. Trench excavation (left) and placement of Electro-Kinetic Geosynthetic (EKG) electrode strips (right) during installation. (Courtesy of Electrokinetic, Ltd., United Kingdom.)Source: FHWA / SHRP2 R02, GeoTechTools.org technology photo sheet.
Cutaway illustration showing installation of electrodes in a slope stabilization project
Photo 7.4.5-2. Cutaway illustration showing the installation of electrodes in a slope stabilization project. (Courtesy of Electrokinetic, Ltd., United Kingdom.)Source: FHWA / SHRP2 R02, GeoTechTools.org technology photo sheet.
Illustration of the electrode pattern, wired for electrokinetic activation
Photo 7.4.5-3. Illustration of the electrode pattern, wired for electrokinetic activation. (Courtesy of Electrokinetic, Ltd., United Kingdom.)Source: FHWA / SHRP2 R02, GeoTechTools.org technology photo sheet.
Slope during electrode installation, with cathode and anode locations labeled
Photo 7.4.5-4. Slope during electrode installation, with tree preservation noted; cathode and anode locations labeled. (Courtesy of Electrokinetic, Ltd., United Kingdom.)Source: FHWA / SHRP2 R02, GeoTechTools.org technology photo sheet.
Close-up of anode and cathode connections during active electrokinetic treatment, with nearby plant growth
Photo 7.4.5-5. Anode (left) and cathode (right) connections during active electrokinetic treatment; nearby plant growth indicates the low impact of the treatment on the surrounding environment. (Courtesy of Electrokinetic, Ltd., United Kingdom.)Source: FHWA / SHRP2 R02, GeoTechTools.org technology photo sheet.
Plan view diagrams of the vertical and horizontal electrode layouts used at the Interstate 40 test section
Photo 7.4.5-6. Plan view diagrams of the vertical-anode and horizontal-anode/cathode electrode layouts used at the Interstate 40 test section, Holbrook, AZ. (From O'Bannon, Morris, and Mancini, 1976; reproduced with permission of the Transportation Research Board.)Source: FHWA / SHRP2 R02, GeoTechTools.org technology photo sheet.
Wiring diagram of the electrode instrumentation used at the Interstate 40 test section
Photo 7.4.5-7. Wiring diagram of the current and voltage instrumentation used at the Interstate 40 test section. (From O'Bannon, Morris, and Mancini, 1976; reproduced with permission of the Transportation Research Board.)Source: FHWA / SHRP2 R02, GeoTechTools.org technology photo sheet.
Plan of electrode and chemical injection point arrangement used at the Seattle-Tacoma Airport runway test section
Photo 7.4.5-8. Plan of the electrode and chemical-injection-point arrangement used at the Seattle-Tacoma Airport runway test section. (Dearstyne and Newman, 1963; with permission of ASCE.)Source: FHWA / SHRP2 R02, GeoTechTools.org technology photo sheet.
Cross section of the saturated runway subgrade with mud and void zones, Seattle-Tacoma Airport
Photo 7.4.5-9. Cross section of the saturated runway subgrade, showing mud and void zones beneath the pavement and the electrode/drain arrangement used to treat them. (Dearstyne and Newman, 1963; with permission of ASCE.)Source: FHWA / SHRP2 R02, GeoTechTools.org technology photo sheet.
Close-up photograph of black perforated GEOWEB strip material showing the diamond-textured surface, perforation holes, and a weld point
Photo 7.4.5-10. Textured, perforated Geoweb strip material. Credit: photographer not stated in the source.Source: Presto Geosystems product literature (GEOWEB® / GEOTERRA®).
Photograph of three workers in high-visibility gear installing expanded black GEOWEB sections down a rock slope, with white geotextile visible beneath the cells
Photo 7.4.5-11. GEOWEB sections expanded and installed over a graded slope. Credit: photographer not stated in the source.Source: Presto Geosystems product literature (GEOWEB® / GEOTERRA®).
Line diagram showing a diamond-shaped Geoweb cell with Cell Length and Cell Width axes and dashed/solid lines illustrating the range of variable expansion
Photo 7.4.5-12. Variable Expansion of the Geoweb Cell. Credit: photographer not stated in the source.Source: Presto Geosystems product literature (GEOWEB® / GEOTERRA®).
Line diagram of an expanded Geoweb honeycomb section with an arrow through the center labeled Direction of Expansion, and Length/Width axis labels
Photo 7.4.5-13. Geoweb Expansion. Credit: photographer not stated in the source.Source: Presto Geosystems product literature (GEOWEB® / GEOTERRA®).
Line diagram of the standalone ATRA Stake Clip, a blue cup-shaped molded polyethylene device with prong-like legs
Photo 7.4.5-14. ATRA® Stake Clip. Credit: photographer not stated in the source.Source: Presto Geosystems product literature (GEOWEB® / GEOTERRA®).
Line diagram of the ATRA Anchor, showing the blue Stake Clip attached as an end cap to a green steel reinforcing rod
Photo 7.4.5-15. ATRA® Anchor. Credit: photographer not stated in the source.Source: Presto Geosystems product literature (GEOWEB® / GEOTERRA®).
Diagram of the ATRA Stake Clip installed over the top of a gray Geoweb cell wall, engaging the arm of the clip over the wall
Photo 7.4.5-16. ATRA® Anchor Connected Over the Cell Wall. Credit: photographer not stated in the source.Source: Presto Geosystems product literature (GEOWEB® / GEOTERRA®).
Diagram showing a blue ATRA Anchor clip driven flush with the base of a Geoweb cell, engaged over a green tendon rod passing through the wall
Photo 7.4.5-17. ATRA® Anchor over Tendon. Credit: photographer not stated in the source.Source: Presto Geosystems product literature (GEOWEB® / GEOTERRA®).
Rendering of the standalone gray ATRA Tendon Clip, a ring-shaped molded polyethylene device with a locking post
Photo 7.4.5-18. ATRA® Tendon Clip. Credit: photographer not stated in the source.Source: Presto Geosystems product literature (GEOWEB® / GEOTERRA®).
Rendering of two Geoweb cell walls each fitted with a gray ATRA Tendon Clip and a yellow tendon passing diagonally through the wall
Photo 7.4.5-19. ATRA® Tendon Clips with Tendons through the Geoweb Cell Wall. Credit: photographer not stated in the source.Source: Presto Geosystems product literature (GEOWEB® / GEOTERRA®).
Photograph of a hand inserting a black T-shaped ATRA Key into the slot between two black Geoweb cell walls
Photo 7.4.5-20. ATRA® Key Geoweb Panel Connection — inserting the key. Credit: photographer not stated in the source.Source: Presto Geosystems product literature (GEOWEB® / GEOTERRA®).

Remedial design should address the cause identified in the investigation, not only the symptom; a wall built across a slide that is driven by a blocked culvert will be loaded by the same water that caused the slide. Retaining structures and ground improvement are covered in Chapter 7.1 and Chapter 7.2, and slope stability analysis in Chapter 6.3.

← Previous · 7.0 Design Chapter 7.3 — Pavement Subgrade Evaluation
Next · 8.0 Reporting → Chapter 8.1 — Exploration Versus Investigation