Many cut and fill slopes along track stand steeper than their friction angle for years and then slide in a wet season. The extra strength comes from matric suction in the soil above the water table, and steady infiltration takes it away. Lu and Likos's Unsaturated Soil Mechanics gives closed-form tools for this. Their Chapter 7 derives the steady suction profile above the water table for a given infiltration or evaporation rate, using Gardner's exponential conductivity function. Their Section 8.2 takes the effective degree of saturation from the van Genuchten water retention curve as Bishop's effective stress parameter χ. Suction then adds a stress Se(ua − uw) to the normal stress on a potential slip plane. Dropping that into the infinite slope equation shows how a slope that is safe in dry weather can fail under steady rain without the water table ever reaching the slip surface.
Equation 6.4-7. Steady suction profile, effective saturation and factor of safety
Se = [1 + (αψ)n]−(1 − 1/n); suction stress = Seγwψ
F = [c′ + (γd cos²β + Seγwψ) tanφ′] / (γd sinβ cosβ); d = slip depth
| Soil | n | α (1/kPa) | α (1/ft of head) | ks (m/s) |
|---|---|---|---|---|
| Sand | 4 to 8.5 | 0.1 to 0.5 | 0.3 to 1.5 | 10−2 to 10−5 |
| Silt | 2 to 4 | 0.01 to 0.1 | 0.03 to 0.3 | 10−6 to 10−9 |
| Clay | 1.1 to 2.5 | 0.001 to 0.01 | 0.003 to 0.03 | 10−8 to 10−13 |
α in 1/ft of suction head = α in 1/kPa × 2.99. Lu and Likos's representative infiltration rate is about 2.7 mm/day (0.11 in./day) and evaporation 1 mm/day.
With no flow the suction equals the height above the water table, which is the hydrostatic case. The solution also has a physical limit: steady infiltration cannot exceed ks, and when it reaches ks the suction falls to zero throughout. As a check, Lu and Likos's representative clay (ks = 0.014 ft/day, or 5 × 10−8 m/s; α = 0.015 per ft of suction head, or 0.005 kPa−1) under their highest infiltration rate gives about 650 psf (31 kPa) of suction 33 ft (10 m) above the water table, against 2,050 psf (98 kPa) with no flow. That is a change of roughly 1,360 psf (65 kPa), consistent with the “about 60 kPa” (1,250 psf) they describe for that case.
A 1.5H:1V (33.7°) silt slope with φ′ = 32°, no cohesion and the water table 15 ft down is checked at a slip depth of 4 ft. Without suction its factor of safety would be 0.94, so it should not stand. With no flow, suction raises it to 2.88. Steady infiltration of 0.1 in./day lowers that to 2.27, and 0.25 in./day to 1.39. Once infiltration matches the silt's conductivity, the slope is back to 0.94 and fails. Drainage cannot help here because there is no water table at the slip depth. What helps is limiting infiltration (ditches above the crest, sealing cracks, vegetation) or flattening the slope.
Open the rainfall and suction calculator →
Steady suction and effective saturation profiles above the water table for a given infiltration or evaporation rate, and the infinite-slope factor of safety with depth, with and without suction.
These documents are in the reference library. The summaries above are paraphrased; equations and tabulated values are standard or published. Individual railroads, clients and projects are not named.