↑ Parent Menu⌂ Main Menu
← Chapter 6.4 Infiltration and Seepage
GHRM
Railway Ground Hazard Risk Management · 6.0 · Analysis
Sections · open a dropdown to go to a section or subsection

6.4.6 Drainage Design

How rainfall and water move into and through railroad fills, slopes and subgrade, how that is measured, and what it does to stability.
Author: Daniel P. Colwell
6.4.6 Drainage Design

Drainage is usually the cheapest and most effective way to reduce the frequency of failure, because it acts directly on the trigger (Table 3.8-79). It only works while it is maintained.

Table 6.4-4. Drainage measures for railroad earthworks
MeasureActs onDesign notes
Ditch cleaning and regradingPonding at the toe; water in the ballastPositive grade to an outlet; invert below the subgrade
Culvert cleaning, upsizing or replacementPonding against the fillCapacity for the design storm (the 100-year event earns the most credit, Table 3.8-81); outlet protection
Subdrains and underdrainsWater in the subgrade and toeFilter-compatible aggregate or geotextile; cleanouts
Toe drains and drainage blanketsSeepage exit at the toeFilter criteria (Table 6.4-2)
Horizontal drainsGroundwater in the slopeSpacing from seepage analysis; monitor outflow
Surface sealing and diversionInfiltration at the crestDivert crest runoff away from cracks
← Previous · 6.0 Analysis Chapter 6.3 — Slope Stability Analysis
Next · 6.0 Analysis → Chapter 6.5 — Seismic Hazard and Liquefaction