GHRMCalculators · Chapter 4.1, Section 4.1.17

Rock Core Recovery and RQD

Companion to Chapter 4.1 · Borings and Sampling, Section 4.1.17 Rock Core Logging: Recovery, RQD and First Estimates of Rock Properties. English units throughout.

Sketch of the inputs

core-rqd····≥ 4 in.≥ 4 in.≥ 4 in.core run lengthRQD = Σ pieces ≥ 4 in. ÷ run length; recovery = total recovered ÷ run; optional Jv​ and UCS

Core run with intact pieces; RQD counts only pieces at least 4 in. long. Not to scale.

Use and limitations

This calculator implements the method described in the manual section linked above. It is for planning, checking and teaching; design values must come from site-specific data, the governing railroad and agency standards, and the judgment of the responsible engineer.

Sources in the library

GHRM · Railway Ground Hazard Risk Management · Daniel P. Colwell