F.3 Bearing Capacity and Deep Foundations

The closed-form equations of soil and rock mechanics used in this manual, 97 entries in nine families, each with its variables, the conditions it assumes, its source and the sections that use it. English units throughout.
Author: Daniel P. Colwell
F.3 Bearing Capacity and Deep Foundations

Ultimate capacity of shallow footings and static axial capacity of piles and shafts.

BC-01General bearing capacity equationqult
qult = c' Nc Fcs Fcd Fci + q Nq Fqs Fqd Fqi + ½ γ B Nγ Fγs Fγd Fγi

Variables. c' = cohesion (psf); q = γ · Df, effective overburden at footing base (psf); γ = effective unit weight below the base (pcf); B = footing width, or B' for eccentric load (ft); N = bearing capacity factors (BC-02); F = shape, depth and inclination factors (BC-03 to BC-05)

Inputs: where each value comes from (6)
SymbolWhat it isComes fromHow to get itTypical range
c'cohesion (psf)Lab testEffective cohesion intercept from the same triaxial or direct-shear tests used for φ'. Take c' = 0 for sands and for long-term design unless tests justify more.0–300 psf · by USCS group
qintermediate value computed on this pageAnother equationComputed: q = γ · D_f, effective overburden at footing base (psf)project-specific
γeffective unit weight below the base (pcf)Lab testWeigh and measure undisturbed tube samples (ASTM D7263); for fill, use the compaction spec. Or compute γ = γd(1 + w).sands 105–135, clays 95–130 pcf · by USCS group
Bfooting width, or B' for eccentric load (ft)Project geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific
Nbearing capacity factors (BC-02)Field testStandard Penetration Test (ASTM D1586); measure hammer energy (ASTM D4633, withdrawn 2025) to correct to N60.loose sand 4–10, dense 30–50 blows/ft · by USCS group
Fintermediate value computed on this pageAnother equationComputed: F = shape, depth and inclination factors (BC-03 to BC-05)project-specific

Use. Shallow footings on soil, Df ≤ about B. Use drained (c', φ') or undrained (su, φ = 0) parameters as the loading requires.

Limitations. Assumes general shear failure. For loose sand or soft clay (local or punching shear) reduce strength (c* = 0.67c', tan φ* = 0.67 tan φ') or check settlement, which usually governs. Use γ' (buoyant) where the water table is within B below the base.

Source. Terzaghi 1943; Meyerhof 1963; Vesić 1973 [57] [38] [63] · In the manual: Ch 6.1 Eq. 6.1-1

BC-02Bearing capacity factorsNc, Nq, Nγ
Nq = eπ tan φ' · tan2(45° + φ'/2)
Nc = (Nq − 1) · cot φ'    (Nc = 5.14 for φ = 0)
Nγ = 2 (Nq + 1) · tan φ'

Variables. φ' = friction angle of the bearing soil (degrees)

Inputs: where each value comes from (2)
SymbolWhat it isComes fromHow to get itTypical range
φ'friction angle of the bearing soil (degrees)Lab test (or correlation)Triaxial CU with pore pressure (ASTM D4767) or CD (D7181), or direct shear (D3080). Sands are rarely sampled: estimate from SPT or CPT correlations (IS-04, IS-05, IS-08).sands 30–42°, clays 17–32° · by USCS group
γtotal (moist) unit weightLab testWeigh and measure undisturbed tube samples (ASTM D7263); for fill, use the compaction spec. Or compute γ = γd(1 + w).sands 105–135, clays 95–130 pcf · by USCS group

Use. With BC-01.

Limitations. Nγ varies widely between authors (Vesić, Meyerhof, Hansen); state which is used. Factors grow very quickly above φ' ≈ 35°, so a few degrees of overestimate in φ' gives a large overestimate in capacity.

Source. Prandtl 1921; Reissner 1924; Vesić 1973 [63] · In the manual: Ch 6.1 Eq. 6.1-2

BC-03Shape factorsFs
Fcs = 1 + (B/L)(Nq/Nc)    Fqs = 1 + (B/L) tan φ'    Fγs = 1 − 0.4 (B/L)

Variables. B, L = footing width and length (ft), L ≥ B; use B', L' for eccentric loads. Strip: B/L = 0; square or circle: B/L = 1

Inputs: where each value comes from (2)
SymbolWhat it isComes fromHow to get itTypical range
φ'effective friction angleLab test (or correlation)Triaxial CU with pore pressure (ASTM D4767) or CD (D7181), or direct shear (D3080). Sands are rarely sampled: estimate from SPT or CPT correlations (IS-04, IS-05, IS-08).sands 30–42°, clays 17–32° · by USCS group
γtotal (moist) unit weightLab testWeigh and measure undisturbed tube samples (ASTM D7263); for fill, use the compaction spec. Or compute γ = γd(1 + w).sands 105–135, clays 95–130 pcf · by USCS group

Use. Rectangular, square and circular footings with BC-01.

Limitations. Empirically calibrated from model tests; do not mix shape factors from one author with Nγ from another.

Source. De Beer 1970, as given by Vesić 1973 [63] · In the manual: Ch 6.1 Eq. 6.1-3

BC-04Depth factorsFd
Df/B ≤ 1:   Fqd = 1 + 2 tan φ' (1 − sin φ')2 (Df/B)
Fcd = Fqd − (1 − Fqd) / (Nc tan φ')    (φ = 0: Fcd = 1 + 0.4 Df/B)    Fγd = 1
Df/B > 1: replace Df/B with tan−1(Df/B) in radians

Variables. Df = embedment depth (ft); B = footing width (ft)

Inputs: where each value comes from (3)
SymbolWhat it isComes fromHow to get itTypical range
Dfembedment depth (ft)Project geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific
Bfooting width (ft)Project geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific
φ'effective friction angleLab test (or correlation)Triaxial CU with pore pressure (ASTM D4767) or CD (D7181), or direct shear (D3080). Sands are rarely sampled: estimate from SPT or CPT correlations (IS-04, IS-05, IS-08).sands 30–42°, clays 17–32° · by USCS group

Use. Embedded footings where the soil above the base is competent and will remain in place.

Limitations. Omit depth factors (set to 1) where the embedment soil may be removed by scour, excavation or trenching, or is loose fill.

Source. Hansen 1970 [23] [63] · In the manual: Ch 6.1 Eq. 6.1-4

BC-05Load inclination factorsFi
Fci = Fqi = (1 − β°/90°)2    Fγi = (1 − β/φ')2

Variables. β = inclination of the resultant load from vertical (degrees); φ' = friction angle (degrees). If β ≥ φ', Fγi = 0

Inputs: where each value comes from (3)
SymbolWhat it isComes fromHow to get itTypical range
βinclination of the resultant load from vertical (degrees)Project geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific
φ'friction angle (degrees)Lab test (or correlation)Triaxial CU with pore pressure (ASTM D4767) or CD (D7181), or direct shear (D3080). Sands are rarely sampled: estimate from SPT or CPT correlations (IS-04, IS-05, IS-08).sands 30–42°, clays 17–32° · by USCS group
γtotal (moist) unit weightLab testWeigh and measure undisturbed tube samples (ASTM D7263); for fill, use the compaction spec. Or compute γ = γd(1 + w).sands 105–135, clays 95–130 pcf · by USCS group

Use. Abutments and wall footings with horizontal thrust.

Limitations. Also check sliding separately (EP-08); a footing can satisfy bearing and still slide.

Source. Meyerhof 1963; Hanna & Meyerhof 1981 [38] · In the manual: Ch 6.1 Eq. 6.1-5

BC-06Undrained bearing capacity of clay (Skempton)qult
qult = su · Nc + q
Nc ≈ 5 · (1 + 0.2 Df/B) · (1 + 0.2 B/L),   Df/B ≤ 2.5    (fit to Skempton's chart; strip limits 5.0 at the surface (exact π + 2 = 5.14) and 7.5 at depth)

Variables. su = undrained shear strength within about B below the base (psf); q = total overburden at the base (psf)

Inputs: where each value comes from (2)
SymbolWhat it isComes fromHow to get itTypical range
suundrained shear strength within about B below the base (psf)Lab or field testLab: UU triaxial (ASTM D2850) or unconfined compression (D2166). Field: vane shear (D2573), CPT su = (qt − σv)/Nkt, or pocket penetrometer/Torvane for screening.soft 250–500, stiff 1,000–2,000 psf · by USCS group
qtotal overburden at the base (psf)Another equationFrom unit weights, layer thicknesses and the groundwater level: σv = Σγihi, u = γw × depth below the water table, σ' = σ − u. Use the design groundwater level.project-specific

Use. Short-term (end-of-construction) capacity of saturated clay; the manual's subgrade allowable stress qu/(π + 2)/FS is this case with qu = 2su.

Limitations. Total-stress analysis: valid only for rapid loading of saturated clay. Correct field vane su with Bjerrum's factor; Nc is capped near 9 for deep foundations.

Source. Skempton 1951 [51] · In the manual: Ch 6.1 §6.1.2, Ch 2.3 §2.3.4

BC-07Eccentric load: effective area and contact pressureB', qmax
eB = MB/P,   eL = ML/P    B' = B − 2eB,   L' = L − 2eL
qmax, min = (P / BL) · (1 ± 6eB/B)    (eB ≤ B/6)
eB > B/6: qmax = 4P / [3L(B − 2eB)]

Variables. P = vertical load (lb); M = moment about the footing centroid (ft-lb); B, L = footing dimensions (ft)

Inputs: where each value comes from (2)
SymbolWhat it isComes fromHow to get itTypical range
Pvertical load (lb)Loading criteriaFrom the loading criteria: AREMA MRE (Cooper E-80, impact), structural loads from the designer, or equipment specifications.project-specific
Mmoment about the footing centroid (ft-lb)Loading criteriaFrom the loading criteria: AREMA MRE (Cooper E-80, impact), structural loads from the designer, or equipment specifications.project-specific

Use. Abutments, wall footings and crane-rail foundations with moment.

Limitations. Use B', L' in BC-01 to BC-05, and full B, L for settlement. AREMA keeps the resultant within the middle third (e ≤ B/6) for unfactored loads.

Source. Meyerhof 1953 [37] [11] · In the manual: Ch 6.1 Eq. 6.1-7, Ch 7.1 §7.1.5

BC-08Allowable bearing pressureqallow
qallow = (qult − q) / FS + q    qnet,allow = (qult − q) / FS

Variables. q = overburden pressure at the base (psf); FS = factor of safety (typically 2.5 to 3.0 for railroad structures)

Inputs: where each value comes from (2)
SymbolWhat it isComes fromHow to get itTypical range
qoverburden pressure at the base (psf)Another equationFrom unit weights, layer thicknesses and the groundwater level: σv = Σγihi, u = γw × depth below the water table, σ' = σ − u. Use the design groundwater level.project-specific
FSfactor of safety (typically 2.5 to 3.0 for railroad structures)Design criterionSet by the client railroad standards, AREMA, AASHTO, USACE or the project specification.typically 2.5 to 3.0 for railroad structures

Use. Converting ultimate to allowable capacity.

Limitations. The FS covers strength uncertainty only. The allowable pressure for design is the lower of this value and the pressure that gives tolerable settlement (SE-01 to SE-03).

Source. Terzaghi & Peck 1967 [59] · In the manual: Ch 6.1 Eq. 6.1-6

BC-09Static axial pile capacityQult
Qult = Qs + Qp = Σ fs,i · As,i + qp · Ap    Qallow = Qult / FS

Variables. fs = unit shaft resistance in layer i (psf); As = shaft surface area in layer i (ft2); qp = unit tip resistance (psf); Ap = tip area (ft2)

Inputs: where each value comes from (4)
SymbolWhat it isComes fromHow to get itTypical range
fsunit shaft resistance in layer i (psf)Chart, table or correction factorRead from the cited chart or table for the site conditions; values listed in the definition.project-specific
Asshaft surface area in layer i (ft^2)Project geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific
qpunit tip resistance (psf)Chart, table or correction factorRead from the cited chart or table for the site conditions; values listed in the definition.project-specific
Aptip area (ft^2)Project geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific

Use. Driven piles and drilled shafts; fs and qp come from BC-10 to BC-12.

Limitations. Static analysis sets the estimate only; confirm with dynamic testing (PDA/CAPWAP) or a load test. Exclude shaft resistance in scourable, liquefiable or downdrag zones.

Source. Hannigan et al. 2016 [21] · In the manual: Ch 6.1 Eq. 6.1-9

BC-10Shaft resistance, effective stress (β) methodfs
fs = β · σ'v    β = K · tan δ

Variables. σ'v = effective vertical stress at mid-layer (psf); K = lateral earth pressure coefficient on the shaft; δ = pile–soil interface friction angle

Inputs: where each value comes from (3)
SymbolWhat it isComes fromHow to get itTypical range
σ'veffective vertical stress at mid-layer (psf)Another equationFrom unit weights, layer thicknesses and the groundwater level: σv = Σγihi, u = γw × depth below the water table, σ' = σ − u. Use the design groundwater level.project-specific
Klateral earth pressure coefficient on the shaftChart, table or correction factorRead from the cited chart or table for the site conditions; values listed in the definition.project-specific
δpile–soil interface friction angleLab test (or fraction of φ')Interface direct shear (ASTM D5321); otherwise δ = 0.6–1.0 φ' depending on the surface (steel, concrete, geosynthetic).0.6–1.0 φ' · by USCS group

Use. Sands, and long-term capacity in clays.

Limitations. The form is analytical, but K and δ are empirical and depend on installation; typical β = 0.25–0.40 for steel H-piles in sand. Do not let fs grow without limit with depth.

Source. Burland 1973 [12] [21] · In the manual: Ch 6.1 Eq. 6.1-12

BC-11Shaft and tip resistance in clay (total stress)fs, qp
fs = α · su    qp = 9 · su

Variables. α = adhesion factor (from the correlations in Chapter 6.1, Equation 6.1-11); su = undrained shear strength (psf)

Inputs: where each value comes from (2)
SymbolWhat it isComes fromHow to get itTypical range
αadhesion factor (from the correlations in Chapter 6.1, Equation 6.1-11)Lab testEffective cohesion intercept from the same triaxial or direct-shear tests used for φ'. Take c' = 0 for sands and for long-term design unless tests justify more.0–300 psf · by USCS group
suundrained shear strength (psf)Lab or field testLab: UU triaxial (ASTM D2850) or unconfined compression (D2166). Field: vane shear (D2573), CPT su = (qt − σv)/Nkt, or pocket penetrometer/Torvane for screening.soft 250–500, stiff 1,000–2,000 psf · by USCS group

Use. Short-term capacity of piles and shafts in saturated clay.

Limitations. α is empirical; see the Empirical Equations reference for its limits. Nc = 9 assumes the tip is at least about 4 diameters into the bearing clay.

Source. Skempton 1951; Tomlinson 1957 [51] [21] · In the manual: Ch 6.1 Eq. 6.1-10

BC-12Pile tip resistance in sandqp
qp = σ'v,tip · Nq* ≤ 0.5 Pa Nq* tan φ' (Meyerhof 1976 limit)

Variables. σ'v,tip = effective vertical stress at the tip (psf); Nq* = bearing capacity factor for deep foundations (Vesić or Meyerhof chart)

Inputs: where each value comes from (2)
SymbolWhat it isComes fromHow to get itTypical range
σ'v,tipeffective vertical stress at the tip (psf)Another equationFrom unit weights, layer thicknesses and the groundwater level: σv = Σγihi, u = γw × depth below the water table, σ' = σ − u. Use the design groundwater level.project-specific
Nq*bearing capacity factor for deep foundations (Vesić or Meyerhof chart)Chart, table or correction factorRead from the cited chart or table for the site conditions; values listed in the definition.project-specific

Use. Driven piles ending in sand or gravel.

Limitations. Nq* is highly sensitive to φ'. Cap qp at the limiting value (often 100–150 tsf for driven piles) and check against CPT or SPT-based methods.

Source. Meyerhof 1976; Vesić 1977 [21] · In the manual: Ch 6.1 Eq. 6.1-14

BC-13Pile group efficiency (Converse–Labarre)η
η = 1 − θ · [ (n − 1) m + (m − 1) n ] / (90 · m · n)    θ = tan−1(D/S) in degrees

Variables. m = number of columns; n = number of rows; D = pile diameter (ft); S = center-to-center spacing (ft)

Inputs: where each value comes from (4)
SymbolWhat it isComes fromHow to get itTypical range
mnumber of columnsChart, table or correction factorRead from the cited chart or table for the site conditions; values listed in the definition.project-specific
nnumber of rowsChart, table or correction factorRead from the cited chart or table for the site conditions; values listed in the definition.project-specific
Dpile diameter (ft)Project geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific
Scenter-to-center spacing (ft)Project geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific

Use. Friction piles in clay at close spacing.

Limitations. Geometric rule, not mechanics. Driven piles in sand typically show η ≥ 1; for clay, also check block failure (BC-14) and use the lower capacity.

Source. Converse–Labarre formula, as given by Bowles 1996 [11] · In the manual: Ch 6.1 Eq. 6.1-17

BC-14Block failure of a pile group in clayQblock
Qblock = 2 Dg (Bg + Lg) · s̄u + Nc · su,tip · Bg · Lg

Variables. Dg = embedded depth of the group (ft); Bg, Lg = plan dimensions of the block around the outer piles (ft); s̄u = average su along the block perimeter (psf); su,tip = su at tip level (psf); Nc from BC-06 (up to 9)

Inputs: where each value comes from (4)
SymbolWhat it isComes fromHow to get itTypical range
Dgembedded depth of the group (ft)Project geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific
s̄uaverage s_u along the block perimeter (psf)Project geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific
su,tips_u at tip level (psf)Lab or field testLab: UU triaxial (ASTM D2850) or unconfined compression (D2166). Field: vane shear (D2573), CPT su = (qt − σv)/Nkt, or pocket penetrometer/Torvane for screening.soft 250–500, stiff 1,000–2,000 psf · by USCS group
Ncintermediate value computed on this pageAnother equationComputed: N_c = from BC-06 (up to 9)project-specific

Use. Closely spaced friction pile groups in clay.

Limitations. Compare with the sum of individual pile capacities × η; the smaller governs.

Source. Terzaghi & Peck 1967 [59] · In the manual: Ch 6.1 Eq. 6.1-18

BC-15Uplift (tension) capacity of a pileQt
Qult,t = Σ fs,t · As + Wp

Variables. fs,t = unit shaft resistance in tension (psf, typically 0.75–0.80 of compression); Wp = effective pile weight (lb)

Inputs: where each value comes from (2)
SymbolWhat it isComes fromHow to get itTypical range
fs,tunit shaft resistance in tension (psf, typically 0.75–0.80 of compression)Chart, table or correction factorRead from the cited chart or table for the site conditions; values listed in the definition.typically 0.75–0.80 of compression
Wpeffective pile weight (lb)Chart, table or correction factorRead from the cited chart or table for the site conditions; values listed in the definition.project-specific

Use. Tension piles, frost-jacking checks and overturning restraint.

Limitations. Use buoyant pile weight below the water table. Frost heave adfreeze is a separate load to be added, not a capacity.

Source. Hannigan et al. 2016 [21] · In the manual: Ch 6.1 Eq. 6.1-19

BC-16Chin hyperbolic extrapolation of a pile load testU
U = Δ / [(Δ/P) − K]

Variables. Δ = pile head settlement at load P; K = intercept of the Δ/P against Δ line; 1/U = its slope

Use. Ultimate capacity from a static test stopped before failure.

Limitations. Hyperbolic fits tend to overestimate capacity; use as an upper estimate and check a settlement-based criterion.

Source. Chin 1972, as given by Brown 2012 (Eq. 98.1) [73] · In the manual: Ch 5.3 §5.3.5.4

BC-17Pile base resistance from CPT (Dutch averaging)qb
qb,ult = 0.9 qc,m;   qb,0.1 = 0.6 qc,m

Variables. qc,m = weighted average cone resistance from 8D above to 4D below the toe; qb,0.1 = base resistance at settlement of 10% of the diameter

Use. Base resistance of piles in sand from CPT soundings.

Limitations. Shaft resistance correlations with qc vary from about qc/10 to qc/40; use BC-12 for the shaft.

Source. Bell and Robinson 2012 (Eqs. 54.13–54.14); Lehane et al. 2005 [75] · In the manual: Ch 6.1 §6.1.5.5

BC-18Low-strain pile integrity test relationsc, t, Δf
c = √(E/ρ);   t = 2L/c;   Z = ρcA;   Δf = c/(2L)

Variables. E, ρ = modulus and density of the pile; L = pile length; A = section area; Z = impedance; Δf = spacing of resonant peaks

Use. Interpreting sonic echo and frequency-response tests; checking pile length.

Limitations. Resolution falls in long piles and stiff ground; confirm suspected defects by cross-hole sonic logging.

Source. French and Turner 2012 (Eqs. 97.1–97.5) [74] · In the manual: Ch 5.3 §5.3.5.4

BC-19High-strain dynamic test: impedance and Case dampingRd
Z = EA/c;   F = Zv;   Rd = J Z vtoe

Variables. F = force; v = particle velocity; J = Case damping factor (sand 0.015–0.06 s/ft to clay 0.18–0.34 s/ft); vtoe = toe velocity

Use. Removing the dynamic (damping) resistance from a dynamic load test to estimate static capacity.

Limitations. Signal matching is preferred to the closed-form Case method; J depends on soil type.

Source. Brown 2012 (Eqs. 98.4–98.9; Table 98.6) [73] · In the manual: Ch 5.3 §5.3.5.4

← Previous · Appendices Appendix D — Typical Soil Properties from Blow Counts, Moisture Content and Liquid Limit
Next · Appendices → Appendix G — ICE Manual Cross-Reference