F.7 Groundwater, Seepage and Wells

The closed-form equations of soil and rock mechanics used in this manual, 97 entries in nine families, each with its variables, the conditions it assumes, its source and the sections that use it. English units throughout.
Author: Daniel P. Colwell
F.7 Groundwater, Seepage and Wells

Darcy flow, laboratory and field permeability tests, flow nets, piping and uplift, and flow to wells and drains.

GW-01Darcy's lawq, v
Q = k · i · A    i = Δh / L
v = k · i    vs = k · i / n

Variables. k = hydraulic conductivity (ft/day); i = hydraulic gradient; A = gross flow area (ft2); v = discharge velocity; vs = seepage (pore) velocity; n = porosity

Inputs: where each value comes from (6)
SymbolWhat it isComes fromHow to get itTypical range
khydraulic conductivity (ft/day)Field or lab testField: pumping test, slug test (ASTM D4044, withdrawn 2024) or packer test. Lab: constant head (D2434) for sands, flexible-wall (D5084) for clays. Hazen k ≈ C·D102 for clean sands only.clean sand 1–100, clay < 0.001 ft/day · by USCS group
ihydraulic gradientChart, table or correction factorRead from the cited chart or table for the site conditions; values listed in the definition.project-specific
Agross flow area (ft^2)Project geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific
vdischarge velocityHydraulic studyFrom the hydraulic model or study (HEC-RAS, FHWA HEC-18), stream gauge records or the drainage design.project-specific
vsseepage (pore) velocityField testSeismic CPT, downhole or crosshole (ASTM D4428 / D7400), or MASW surface waves.soft clay 250–500, dense sand 800–1,600 ft/s · by USCS group
nporosityAnother equationn = e/(1 + e), from the void ratio.0.25–0.55 for most mineral soils · by USCS group

Use. Laminar flow in soil.

Limitations. Turbulent flow in open-graded ballast and coarse gravel departs from Darcy. Field k can differ from laboratory k by orders of magnitude.

Source. Darcy 1856 [17] · In the manual: Ch 2.8 Eq. 2.8-11, Ch 2.8 Eq. 2.8-13

GW-02Constant-head permeability testk
k = Q · L / (A · Δh · t)

Variables. Q = volume collected (ft3) in time t (s); L = specimen length (ft); A = specimen area (ft2); Δh = head difference (ft)

Inputs: where each value comes from (4)
SymbolWhat it isComes fromHow to get itTypical range
Qvolume collected (ft^3) in time t (s)Field or lab measurementRecorded during the test or monitoring (readings, times, dimensions of the test setup).project-specific
Lspecimen length (ft)Test setupDimension of the test equipment or specimen: from the test standard or the lab/field test record.project-specific
Aspecimen area (ft^2)Test setupDimension of the test equipment or specimen: from the test standard or the lab/field test record.project-specific
Δhhead difference (ft)Field or lab measurementRecorded during the test or monitoring (readings, times, dimensions of the test setup).project-specific

Use. Clean sands and gravels.

Limitations. Use de-aired water and keep gradients low to stay laminar.

Source. ASTM D2434 [17] · In the manual: Ch 2.8 Eq. 2.8-6

GW-03Falling-head permeability testk
k = (a · L / (A · t)) · ln(h1 / h2)

Variables. a = standpipe area (ft2); h1, h2 = heads at the start and end of time t (ft)

Inputs: where each value comes from (1)
SymbolWhat it isComes fromHow to get itTypical range
astandpipe area (ft^2)Test setupDimension of the test equipment or specimen: from the test standard or the lab/field test record.project-specific

Use. Silts and clays.

Limitations. Confirm saturation (B-value) before testing.

Source. ASTM D5084 [17] · In the manual: Ch 2.8 Eq. 2.8-7

GW-04Equivalent permeability of layered soilkh, kv
kh,eq = Σ ki Hi / Σ Hi    kv,eq = Σ Hi / Σ (Hi / ki)

Variables. ki, Hi = permeability and thickness of layer i

Use. Stratified alluvium and embankment fill.

Limitations. Thin continuous sand seams control kh; a single clay layer controls kv.

Source. Harr 1962 [24] · In the manual: Ch 2.8 §2.8.5

GW-05Flow net seepage and exit gradientq, ie
q = k · H · (Nf / Nd)    ie = (H / Nd) / ℓ

Variables. H = total head loss (ft); Nf = number of flow channels; Nd = number of equipotential drops; ℓ = length of the last flow-net square at the exit (ft); q in ft3/day per ft

Inputs: where each value comes from (4)
SymbolWhat it isComes fromHow to get itTypical range
Htotal head loss (ft)Field or lab measurementRecorded during the test or monitoring (readings, times, dimensions of the test setup).project-specific
Nfnumber of flow channelsHydraulic studyFrom the hydraulic model or study (HEC-RAS, FHWA HEC-18), stream gauge records or the drainage design.project-specific
Ndnumber of equipotential dropsChart, table or correction factorRead from the cited chart or table for the site conditions; values listed in the definition.project-specific
ℓlength of the last flow-net square at the exit (ft)Project geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific

Use. Steady seepage under or through embankments and cofferdams.

Limitations. For anisotropic soil, draw the net on a transformed section (x scaled by √(kv/kh)) and use k = √(khkv).

Source. Forchheimer; Cedergren 1989 [14] · In the manual: Ch 2.8 Eq. 2.8-14

GW-06Critical gradient, piping and uplifticr, FS
icr = γ' / γw = (Gs − 1) / (1 + e)    FSpiping = icr / ie
Blanket uplift: FS = σv / u = Σ γi ti / (γw hp)

Variables. γ' = buoyant unit weight (pcf); ti = thickness of each blanket layer (ft); hp = piezometric head at the base of the blanket above its base (ft)

Inputs: where each value comes from (4)
SymbolWhat it isComes fromHow to get itTypical range
γ'buoyant unit weight (pcf)Another equationγ' = γsat − γw (γw = 62.4 pcf). Use below the water table.50–75 pcf for most mineral soils · by USCS group
tithickness of each blanket layer (ft)Project geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific
hppiezometric head at the base of the blanket above its base (ft)Field measurementGroundwater level from boring logs, observation wells or piezometers (ASTM D5092 / D4750); design with the seasonal high level.project-specific
Gsspecific gravity of solidsLab testSpecific gravity of solids (ASTM D854). 2.65–2.70 is usually adequate for mineral soils when untested.2.64–2.80 mineral; lower if organic · by USCS group

Use. Toe of embankments next to waterways, excavation bottoms and boils.

Limitations. Use large factors (the manual cites FS ≥ 4.0 for piping) because exit gradients are hard to estimate.

Source. Terzaghi 1943 [57] [14] · In the manual: Ch 2.8 Eq. 2.8-15, Ch 2.8 Eq. 2.8-16

GW-07Steady flow to a well, confined aquifer (Thiem)Q
Q = 2π k b (h2 − h1) / ln(r2 / r1)

Variables. b = aquifer thickness (ft); h1, h2 = heads at radial distances r1, r2 (ft); Q in ft3/day (1 gpm = 192.5 ft3/day)

Inputs: where each value comes from (1)
SymbolWhat it isComes fromHow to get itTypical range
baquifer thickness (ft)Project geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific

Use. Dewatering estimates and analysis of steady-state pumping tests.

Limitations. Fully penetrating well, homogeneous isotropic aquifer, steady state.

Source. Thiem 1906 [60] · In the manual: Ch 2.8 §2.8.6

GW-08Steady flow to a well, unconfined aquifer (Dupuit–Thiem)Q
Q = π k (H2 − hw2) / ln(R / rw)

Variables. H = saturated thickness before pumping (ft); hw = water depth in the well (ft); R = radius of influence (ft); rw = well radius (ft)

Inputs: where each value comes from (4)
SymbolWhat it isComes fromHow to get itTypical range
Hsaturated thickness before pumping (ft)Project geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific
hwwater depth in the well (ft)Field measurementGroundwater level from boring logs, observation wells or piezometers (ASTM D5092 / D4750); design with the seasonal high level.project-specific
Rradius of influence (ft)Project geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific
rwwell radius (ft)Test setupDimension of the test equipment or specimen: from the test standard or the lab/field test record.project-specific

Use. Wellpoint and deep-well yield in water-table aquifers.

Limitations. Dupuit assumes horizontal flow; drawdown at the well is under-predicted when it is large. Q is not sensitive to R because R enters through a logarithm.

Source. Dupuit 1863; Thiem 1906 [19] [60] · In the manual: Ch 2.8 Eq. 2.8-19

GW-09Transient pumping test (Cooper–Jacob)T, S
s = (2.303 Q / 4πT) · log10(2.25 T t / (r2 S))
T = 2.303 Q / (4π Δs)    S = 2.25 T t0 / r2    k = T / b

Variables. s = drawdown (ft); T = transmissivity (ft2/day); S = storativity; Δs = drawdown per log cycle of time (ft); t0 = zero-drawdown time intercept (days); r = distance to the observation well (ft)

Inputs: where each value comes from (6)
SymbolWhat it isComes fromHow to get itTypical range
sdrawdown (ft)Field or lab measurementRecorded during the test or monitoring (readings, times, dimensions of the test setup).project-specific
Ttransmissivity (ft^2/day)Chart, table or correction factorRead from the cited chart or table for the site conditions; values listed in the definition.project-specific
SstorativityChart, table or correction factorRead from the cited chart or table for the site conditions; values listed in the definition.project-specific
Δsdrawdown per log cycle of time (ft)Field or lab measurementRecorded during the test or monitoring (readings, times, dimensions of the test setup).project-specific
t0zero-drawdown time intercept (days)Field or lab measurementRecorded during the test or monitoring (readings, times, dimensions of the test setup).project-specific
rdistance to the observation well (ft)Project geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific

Use. Confined aquifer pumping tests.

Limitations. Valid when u = r2S / (4Tt) ≤ 0.01 (some references accept 0.05); discard early-time data that do not meet it.

Source. Cooper & Jacob 1946 [15] · In the manual: Ch 2.8 Eq. 2.8-8, Ch 2.8 Eq. 2.8-10

GW-10Slug test (Bouwer–Rice)k
k = [ rc2 · ln(Re / rw) / (2 Le) ] · (1/t) · ln(y0 / yt)

Variables. rc = casing radius (ft); rw = effective well radius (ft); Re = effective radius from the Bouwer–Rice coefficients (ft); Le = screen length (ft); y0, yt = head displacement at the start and at time t

Inputs: where each value comes from (4)
SymbolWhat it isComes fromHow to get itTypical range
rccasing radius (ft)Test setupDimension of the test equipment or specimen: from the test standard or the lab/field test record.project-specific
rweffective well radius (ft)Test setupDimension of the test equipment or specimen: from the test standard or the lab/field test record.project-specific
Reeffective radius from the Bouwer–Rice coefficients (ft)Chart, table or correction factorRead from the cited chart or table for the site conditions; values listed in the definition.project-specific
Lescreen length (ft)Test setupDimension of the test equipment or specimen: from the test standard or the lab/field test record.project-specific

Use. Hydraulic conductivity of the soil around a monitoring well or piezometer.

Limitations. Tests only a small volume; a poorly developed screen gives low k.

Source. Bouwer & Rice 1976 [10] · In the manual: Ch 2.8 Eq. 2.8-5

GW-11Unconfined flow to a drain (Dupuit)q
q = k (h12 − h22) / (2L)

Variables. h1, h2 = saturated heights above the impermeable base at the source and at the drain (ft); L = flow length (ft); q in ft3/day per ft of drain

Inputs: where each value comes from (1)
SymbolWhat it isComes fromHow to get itTypical range
Lflow length (ft)Project geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific

Use. Sizing longitudinal subdrains and side ditches that lower the water table under track.

Limitations. Horizontal flow; add rainfall infiltration separately where it is significant.

Source. Dupuit 1863 [19] [14] · In the manual: Ch 2.3 §2.3.8

GW-12Unsaturated hydraulic conductivity (Mualem–van Genuchten)k(Se)
k = ks Se0.5 [1 − (1 − Se1/m)m]2, m = 1 − 1/n

Variables. ks = saturated conductivity; Se = effective saturation from the van Genuchten water retention curve; n = van Genuchten parameter

Use. Seasonal infiltration and pore pressure in unsaturated fill.

Limitations. Conductivity is lower on wetting than drying at the same suction (hysteresis); field data for dumped fills are scarce.

Source. van Genuchten 1980; applied to railway embankments by O'Brien 2013 [76] [67] · In the manual: Ch 6.4 §6.4.12