At-rest, active, passive and seismic earth pressure, surcharge from track loads, and the external stability of walls.
Variables. φ' = friction angle; OCR = overconsolidation ratio; σ'v = effective vertical stress (psf)
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| φ' | friction angle | Lab test (or correlation) | Triaxial CU with pore pressure (ASTM D4767) or CD (D7181), or direct shear (D3080). Sands are rarely sampled: estimate from SPT or CPT correlations (IS-04, IS-05, IS-08). | sands 30–42°, clays 17–32° · by USCS group |
| OCR | overconsolidation ratio | Lab test (or correlation) | Preconsolidation stress from the consolidation curve (Casagrande or work method, ASTM D2435). CPT screening: σ'p ≈ 0.33(qt − σv). OCR = σ'p/σ'v0. | OCR 1 (NC) to > 4 (heavily OC) · by USCS group |
| σ'v | effective vertical stress (psf) | Another equation | From unit weights, layer thicknesses and the groundwater level: σv = Σγihi, u = γw × depth below the water table, σ' = σ − u. Use the design groundwater level. | project-specific |
Use. Walls that cannot move (culvert walls, braced or restrained abutments).
Limitations. Semi-empirical; compaction behind a rigid wall can raise lateral pressure above K0 near the top.
Source. Jaky 1944; Mayne & Kulhawy 1982 [28] [35] · In the manual: Ch 7.1 §7.1.2
Variables. σ'v = effective vertical stress at depth (psf); c' = effective cohesion (psf)
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| σ'v | effective vertical stress at depth (psf) | Another equation | From unit weights, layer thicknesses and the groundwater level: σv = Σγihi, u = γw × depth below the water table, σ' = σ − u. Use the design groundwater level. | project-specific |
| c' | effective cohesion (psf) | Lab test | Effective cohesion intercept from the same triaxial or direct-shear tests used for φ'. Take c' = 0 for sands and for long-term design unless tests justify more. | 0–300 psf · by USCS group |
| φ' | effective friction angle | Lab test (or correlation) | Triaxial CU with pore pressure (ASTM D4767) or CD (D7181), or direct shear (D3080). Sands are rarely sampled: estimate from SPT or CPT correlations (IS-04, IS-05, IS-08). | sands 30–42°, clays 17–32° · by USCS group |
Use. Vertical, frictionless back face with level backfill; the AREMA standard case with c' = 0.
Limitations. Active pressure needs wall movement of roughly 0.001H (dense sand) to 0.004H (loose sand); passive needs about ten times more. Neglect negative active pressure from c'.
Source. Rankine 1857 [46] · In the manual: Ch 7.1 §7.1.2
Variables. β = backfill slope angle above horizontal (β ≤ φ')
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| β | backfill slope angle above horizontal (β ≤ φ') | Project geometry | From project plans, survey and the design layout; layer depths and thicknesses from the boring logs. | project-specific |
| φ' | effective friction angle | Lab test (or correlation) | Triaxial CU with pore pressure (ASTM D4767) or CD (D7181), or direct shear (D3080). Sands are rarely sampled: estimate from SPT or CPT correlations (IS-04, IS-05, IS-08). | sands 30–42°, clays 17–32° · by USCS group |
Use. Cantilever walls with a sloping backfill, using the vertical plane through the heel.
Limitations. Not defined for β > φ'.
Source. Rankine 1857 [46] · In the manual: Ch 7.1 §7.1.2
Variables. α = angle of the wall back face from horizontal (90° vertical); δ = wall friction angle; β = backfill slope above horizontal
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| α | angle of the wall back face from horizontal (90° vertical) | Project geometry | From project plans, survey and the design layout; layer depths and thicknesses from the boring logs. | project-specific |
| δ | wall friction angle | Lab test (or fraction of φ') | Interface direct shear (ASTM D5321); otherwise δ = 0.6–1.0 φ' depending on the surface (steel, concrete, geosynthetic). | 0.6–1.0 φ' · by USCS group |
| β | backfill slope above horizontal | Project geometry | From project plans, survey and the design layout; layer depths and thicknesses from the boring logs. | project-specific |
| φ' | effective friction angle | Lab test (or correlation) | Triaxial CU with pore pressure (ASTM D4767) or CD (D7181), or direct shear (D3080). Sands are rarely sampled: estimate from SPT or CPT correlations (IS-04, IS-05, IS-08). | sands 30–42°, clays 17–32° · by USCS group |
Use. Gravity, semi-gravity and MSE walls where wall friction acts.
Limitations. Coulomb Kp is unconservative for δ > φ'/2; use log-spiral values for passive resistance.
Source. Coulomb 1776 [16] · In the manual: Ch 7.1 §7.1.2
Variables. H = wall height (ft); γ = backfill unit weight (pcf); q = uniform surcharge (psf; Cooper E-80 equivalent 400 psf × DLF in the manual); thrust in lb/ft
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| H | wall height (ft) | Project geometry | From project plans, survey and the design layout; layer depths and thicknesses from the boring logs. | project-specific |
| γ | backfill unit weight (pcf) | Lab test | Weigh and measure undisturbed tube samples (ASTM D7263); for fill, use the compaction spec. Or compute γ = γd(1 + w). | sands 105–135, clays 95–130 pcf · by USCS group |
| q | uniform surcharge (psf | Loading criteria | From the loading criteria: AREMA MRE (Cooper E-80, impact), structural loads from the designer, or equipment specifications. | project-specific |
| γ' | buoyant unit weight | Another equation | γ' = γsat − γw (γw = 62.4 pcf). Use below the water table. | 50–75 pcf for most mineral soils · by USCS group |
Use. Wall design loads.
Limitations. A uniform surcharge is a simplification for track loads close to the wall; use EP-06 when the track is within about H of the wall.
Source. Rankine 1857; AREMA MRE Ch. 8 [46] [1] · In the manual: Ch 7.1 §7.1.2, Ch 7.1 §7.1.3
Variables. q = strip pressure (psf); β = angle subtended by the strip at the point on the wall (radians); α = angle from the vertical to the bisector of β (radians); QL = line load (lb/ft); x = distance from the wall to the line load (ft); n = z/H
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| q | strip pressure (psf) | Chart, table or correction factor | Read from the cited chart or table for the site conditions; values listed in the definition. | project-specific |
| β | angle subtended by the strip at the point on the wall (radians) | Project geometry | From project plans, survey and the design layout; layer depths and thicknesses from the boring logs. | project-specific |
| α | angle from the vertical to the bisector of β (radians) | Project geometry | From project plans, survey and the design layout; layer depths and thicknesses from the boring logs. | project-specific |
| QL | line load (lb/ft) | Loading criteria | From the loading criteria: AREMA MRE (Cooper E-80, impact), structural loads from the designer, or equipment specifications. | project-specific |
| x | distance from the wall to the line load (ft) | Project geometry | From project plans, survey and the design layout; layer depths and thicknesses from the boring logs. | project-specific |
| n | intermediate value computed on this page | Another equation | Computed: n = z/H | project-specific |
Use. Track loads parallel to an abutment or wall; the strip form is the AREMA basis for Cooper E-80 surcharge.
Limitations. Boussinesq solutions doubled for an unyielding wall; overestimate pressure on walls that can yield. Use the dynamic track load as q.
Source. Terzaghi 1954; NAVFAC 1986; AREMA MRE Ch. 8 [58] [40] [1] · In the manual: Ch 7.1 §7.1.3
Variables. ψ = batter of the wall back face from vertical (0 for a vertical wall); β = backfill slope; kh, kv = seismic coefficients (fractions of g)
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| ψ | batter of the wall back face from vertical (0 for a vertical wall) | Lab or field test | Lab: UU triaxial (ASTM D2850) or unconfined compression (D2166). Field: vane shear (D2573), CPT su = (qt − σv)/Nkt, or pocket penetrometer/Torvane for screening. | soft 250–500, stiff 1,000–2,000 psf · by USCS group |
| β | backfill slope | Project geometry | From project plans, survey and the design layout; layer depths and thicknesses from the boring logs. | project-specific |
| φ' | effective friction angle | Lab test (or correlation) | Triaxial CU with pore pressure (ASTM D4767) or CD (D7181), or direct shear (D3080). Sands are rarely sampled: estimate from SPT or CPT correlations (IS-04, IS-05, IS-08). | sands 30–42°, clays 17–32° · by USCS group |
| γ | total (moist) unit weight | Lab test | Weigh and measure undisturbed tube samples (ASTM D7263); for fill, use the compaction spec. Or compute γ = γd(1 + w). | sands 105–135, clays 95–130 pcf · by USCS group |
Use. Yielding walls with dry cohesionless backfill.
Limitations. Requires φ' − θ − β ≥ 0; no solution otherwise. The wall angle here is measured from vertical (unlike EP-04). Not for saturated backfill without hydrodynamic terms.
Source. Okabe 1926; Mononobe & Matsuo 1929 [43] [39] [49] · In the manual: Ch 7.1 §7.1.7
Variables. ΣV = total vertical load on the base (lb/ft); δb = base friction angle; ca = base adhesion (psf); Pp = passive resistance relied on (lb/ft); ΣPh = horizontal driving forces; MR, MO = resisting and overturning moments about the toe (ft-lb/ft)
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| ΣV | total vertical load on the base (lb/ft) | Loading criteria | From the loading criteria: AREMA MRE (Cooper E-80, impact), structural loads from the designer, or equipment specifications. | project-specific |
| δb | base friction angle | Lab test (or fraction of φ') | Interface direct shear (ASTM D5321); otherwise δ = 0.6–1.0 φ' depending on the surface (steel, concrete, geosynthetic). | 0.6–1.0 φ' · by USCS group |
| ca | base adhesion (psf) | Lab test | Effective cohesion intercept from the same triaxial or direct-shear tests used for φ'. Take c' = 0 for sands and for long-term design unless tests justify more. | 0–300 psf · by USCS group |
| Pp | passive resistance relied on (lb/ft) | Chart, table or correction factor | Read from the cited chart or table for the site conditions; values listed in the definition. | project-specific |
| ΣPh | horizontal driving forces | Loading criteria | From the loading criteria: AREMA MRE (Cooper E-80, impact), structural loads from the designer, or equipment specifications. | project-specific |
Use. Cantilever, gravity and semi-gravity walls.
Limitations. Count passive resistance only below frost depth and below any soil that may be excavated. Also check bearing (BC-01, BC-07) and global stability (SL-05).
Source. Bowles 1996; AREMA MRE Ch. 8 [11] [1] · In the manual: Ch 7.1 §7.1.5, Ch 7.1 §16.9
Variables. P = effective roller line load (lb/ft); γ = fill unit weight; envelope σv/K0 to zcr, constant to hc, then K0σv
Use. Rigid walls, headwalls and abutments with compacted backfill.
Limitations. For walls that do not yield to the active state; add surcharge and water separately.
Source. Pickles 2012 (Eqs. 64.1–64.3) [71] · In the manual: Ch 7.1 §7.1.19
Variables. b = pile width; z = depth below excavation; p′v = effective overburden there; spacing s > 3b; divide by s for per-foot-of-wall values
Use. Embedment of soldier piles below an excavation.
Limitations. Ultimate values; valid for Kp 3.0–5.3. Vol. II prints ≤ in both depth limits; the second of each pair is evidently ≥.
Source. Pickles 2012 (Eqs. 64.5–64.8), after Barton 1982 and Fleming et al. 1994 [71] · In the manual: Ch 7.1 §7.1.4.7
Variables. cv = coefficient of consolidation; t = time the excavation is open
Use. su taken as zero at the excavation level rising to the design value at depth L.
Limitations. Where no groundwater recharge is possible, use about 1.6 ft (0.5 m).
Source. Pickles 2012 (Eq. 64.4) [71] · In the manual: Ch 7.1 §7.1.4.7
Variables. d = borehole diameter; L = fixed anchor length; τult = grout–ground bond (in clay αcu); F = global factor
Use. Preliminary fixed length of tiebacks.
Limitations. Bond values must be confirmed by anchor tests.
Source. Turner 2012 (Eqs. 66.1–66.6) [72] · In the manual: Ch 7.1 §7.1.4.7