Utility crossings are one of the most common reasons for borings on railroad right-of-way, and one of the most common causes of track settlement when the bore is poorly controlled. AREMA Chapter 1, Part 5, sets the depth, casing and length requirements, and railroad pipeline specifications add the boring program: borings on each side of the track on the crossing centerline, sampled continuously to 5 ft below the proposed invert (rock cored), and grouted full depth. A 2020 conference paper on trenchless risks stresses settlement monitoring of the ground, not just the rails, since loaded rails can bridge a void until it collapses.
| Item | Requirement |
|---|---|
| Casing depth | 5 1/2 ft base of rail to top of casing (4 1/2 ft under secondary or industry track); 3 ft below ground or ditch elsewhere |
| Uncased steel carrier (secondary or industry track) | 10 ft below base of rail; 6 ft below ground or ditch elsewhere |
| Casing length, each side, measured from the centerline of the outside track | Greatest of 2 ft beyond toe of slope, 3 ft beyond ditch, 25 ft (sealed ends) or 45 ft (open ends) |
| Steel casing inside diameter | Carrier OD (joints, couplings) + 2 in. under 6 in.; + 4 in. for 6 in. and over |
| Steel casing material | Minimum yield 35,000 psi; wall per Table 1-5-1 (thicker if uncoated and unprotected) |
| Bored hole | About the pipe OD; more than about 1 in. oversize calls for remedial measures (grouting) |
| Cover from base of tie (ft) | 2 | 5 | 8 | 10 | 12 | 15 | 20 | 30 |
|---|---|---|---|---|---|---|---|---|
| Live load (psf) | 3,800 | 2,400 | 1,600 | 1,100 | 800 | 600 | 300 | 100 |
Over 30 ft of cover, use dead load only.
| Item | Result |
|---|---|
| Depth, base of rail to top of casing | 6.50 ft |
| E80 live load at 5.85 ft of cover | 2,173 psf |
| Total vertical pressure (with 120 pcf soil) | 2,953 psf |
| Casing wall, coated | 0.406 in. |
| Casing inside diameter for a 24 in. carrier | 29.19 in. |
| Casing length (sealed, tracks 14 ft apart) | 64 ft |
| Bore overcut on diameter | 1.00 in. |
| Boring depth (invert + 5 ft) | 14.0 ft |
The 31 in. bore is at the limit of the AREMA overcut; the annulus should be grouted as the casing advances, and settlement points should be set on the ground at the track before boring starts.
Open the pipeline crossing calculator →
Depth checks, E80 live load at the pipe, minimum casing wall, casing size and length, bore overcut and boring depth.
These documents are in the reference library. The summaries above are paraphrased; equations and tabulated limits are standard or published values. Individual railroads are not named.