Table 3.3-4. Sampling and field tests| Method | Use | Specification notes |
|---|
| Standard Penetration Test (SPT) | All soils; strength and density correlations | 5-ft intervals as a default; continuous in the upper 10 ft or where conditions change; record hammer type and efficiency |
| Shelby (thin-wall) tubes | Soft to stiff clay and silt; consolidation and strength tests | 3-in. diameter; two per boring where soft clay is found; from an offset boring if needed; sealed and kept upright |
| Rock coring | Rock quality, strength, joints, voids | NQ (about 2 in.) core; RQD and recovery; coring contingency where refusal depth is uncertain |
| Dynamic cone penetrometer (DCP) | Pavement subgrade strength; CBR correlation | To 5 ft beside pavement borings; usually covered by the driller's day rate |
| Pocket penetrometer and torvane | Field strength of cohesive samples | Every cohesive SPT and tube end |
| Bulk samples | Proctor, CBR, resilient modulus | About 50 lb per sample from the subgrade zone |
| Photo-ionization detector (PID) | Screening in fill, slag and odor areas | Every sample in fill; drum cuttings if readings or odors indicate impacted material |
| Hand-auger probes | Soft-soil depth, ditch conditions | Between borings; cheap and fast where access is poor |