Every boring needs a stated purpose. If the purpose cannot be written in one line, the boring is either in the wrong place or not needed. Typical purposes on railroad work are: the foundation soils and depth to rock under the toe of a fill that is being steepened; the bearing stratum for a light-tower or signal foundation; the subgrade for heavy-duty pavement; the soft-soil depth for undercut limits; and conditions below a proposed ditch grade.
| Question | Exploration that answers it |
|---|---|
| Will a steepened 1.5H:1V fill be stable? | Borings at the toe of the new slope to rock or below the critical slip surface; Shelby tubes in soft clay for strength; rock core where refusal is shallow |
| What will carry a high-mast light tower? | One boring per tower to below the expected shaft tip (35 ft in one recent program); SPT at 5-ft intervals |
| What subgrade will heavy pavement sit on? | Shallow borings on a grid (10 ft) with dynamic cone penetrometer (DCP) testing to 5 ft; bulk samples for Proctor and CBR |
| How deep is the soft soil to be undercut? | Hand-auger probes between borings |
| What is below a new ditch grade? | Short borings or hand augers to below the proposed invert (6 ft in one recent program) |
| What is the groundwater regime? | Water at drilling, completion and 24 hours; observation wells or piezometers where seepage controls the design |