↑ Parent Menu⌂ Main Menu
← Chapter 3.2 Desktop Study
GHRM
Railway Ground Hazard Risk Management · 3.0 · Risk Management
Sections · open a dropdown to go to a section or subsection

3.2.6 Preliminary Site Model and Data Gaps

Building a preliminary site model from the office before anyone goes to the field: maps, records, history and hazards.
Author: Daniel P. Colwell
3.2.6 Preliminary Site Model and Data Gaps

Finish with an expected profile, stated as a simple table with depth ranges, and a list of what the borings must answer. The profile below, assembled from 43 legacy borings for a parking expansion, set the depths of both the light-tower and the pavement borings.

Table 3.2-6. Example expected profile from legacy borings
Depth (typical)StratumNotes
0 to 1 ftTopsoil, gravel or asphaltTopsoil often mixed with cinders
0.5 to 3 to 6 ftSlag, cinder and urban fillVery dense, cemented slag; auger refusal in several borings; chemical odor in one
3 to 6 ft (local)Organic clay and peatWater content over 100 percent; drives settlement
4 to 8 to 13.5 ftLacustrine sand and siltVery loose to medium dense, saturated; N typically 2 to 8
8 to 13.5 to 30+ ftGlacial tillStiff to very stiff lean to fat clay; Qu about 1.0 to 3.7 tsf; no legacy boring below 30 ft
1 to 6 ftGroundwaterClose to the lake level
Write the data gaps as questions. "No legacy boring went below 30 ft" becomes "Where is the bottom of the till, and what is below it?" and sets the light-tower borings at 35 ft.

The same model drives design implications: light-tower shafts will need casing or slurry through the loose saturated sand and will take their capacity in the till; pavement subgrade will need undercut and geosynthetics or full-depth reclamation; organic pockets control settlement; slag and odors call for screening and a cuttings plan.

← Previous · 3.0 Risk Management Chapter 3.1 — Scoping Proposals
Next · 3.0 Risk Management → Chapter 3.3 — Drilling Scope