↑ Parent Menu⌂ Main Menu
← Chapter 2.9 Collapsible Soils: Identification, Testing and Railroad Impacts
GHRM
Railway Ground Hazard Risk Management · 2.0 · The Underworld
Sections · open a dropdown to go to a section or subsection

2.9.3 Screening Criteria

Dry, low-density soils that hold their shape until they get wet, then lose volume suddenly under the load they already carry.
Author: Daniel P. Colwell
2.9.3 Screening Criteria

Screening criteria use index properties to decide which samples go to collapse testing. None of them predicts the amount of collapse; they flag soils that need testing.

wsat = γw / γd − 1 / Gs(Eq. 2.9-1)
Moisture content at full saturation for the natural dry unit weight. Gibbs criterion: if wsat > LL the soil can collapse to a density at which, saturated, it is wetter than its liquid limit.
S = w Gs / e(Eq. 2.9-2)
Degree of saturation. Collapse is rarely significant above about S = 60 to 70%.
Table 2.9-2. Screening indicators
IndicatorSuggests collapse whenNotes
Gibbs criterion (Eq. 2.9-1)wsat > LLBest for loess and silty soils
Dry unit weightγd < about 90 pcf (silts), 100 pcf (sands)Rule of thumb only
Degree of saturation (Eq. 2.9-2)S < about 60%Natural moisture from samples sealed in the field
Fines content10 to 40% clay-size bonding fines in a silt or sandClean sands rarely collapse; fat clays swell instead
Field soak testLarge strength loss after wettingQualitative

Use undisturbed samples for natural moisture and density. Split-spoon samples are disturbed and usually overstate density in loose collapsible soil; thin-walled tubes or block samples from test pits are preferred (see Chapter 4.1).

← Previous · 2.0 The Underworld Chapter 2.8 — Groundwater Characterization and Seepage
Next · 2.0 The Underworld → Chapter 2.10 — Non-Engineered Fills: Old Embankments, Waste and Made Ground