Some ground problems are chemical rather than mechanical. Sulfate in soil and groundwater attacks concrete and reacts with lime and cement to form expansive minerals. Pyrite (iron sulfide) in shale oxidizes when exposed to air and water, producing acid and sulfate and swelling the rock. Many shales and claystones slake and lose strength within months of excavation. This chapter covers how to recognize these conditions, the tests that identify them and the design responses for concrete, stabilization and cut slopes.
These problems share two features. First, they are invisible in an ordinary boring log: a gray clay with sulfate or a dark shale with pyrite looks the same as one without. Second, they are triggered by the project itself: by adding lime or cement, by placing concrete, or by exposing rock to air and water in a cut. The investigation has to test for them specifically, and the trigger is something the designer controls.
Water-soluble sulfates (mainly from gypsum and sodium and magnesium sulfates) react with the hydrated cement in concrete to form expansive products that crack and soften it. Culverts, footings, piles, retaining walls and drainage structures in contact with sulfate-bearing soil or water are at risk. Design is by exposure class, based on the water-soluble sulfate content of the soil or the sulfate concentration in the water.
| Class | Water-soluble SO4 in soil (% by mass) | SO4 in water (ppm) | Typical requirements |
|---|---|---|---|
| S0 | < 0.10 | < 150 | No special requirement |
| S1 | 0.10 to < 0.20 | 150 to < 1,500 | Moderate sulfate resistance (e.g., Type II); w/cm ≤ 0.50; f′c ≥ 4,000 psi |
| S2 | 0.20 to 2.00 | 1,500 to 10,000 | High sulfate resistance (e.g., Type V); w/cm ≤ 0.45; f′c ≥ 4,500 psi |
| S3 | > 2.00 | > 10,000 | Type V plus pozzolan or slag; w/cm ≤ 0.45; f′c ≥ 4,500 psi |
Note the units: laboratories often report soil sulfate in parts per million (mg/kg). 1,000 ppm equals 0.10% by mass. Precast culvert and pipe suppliers should be given the exposure class in the specifications.
When lime or cement is mixed into a sulfate-bearing clay, calcium, aluminum (from the clay) and sulfate combine in the presence of water to form ettringite, a mineral that occupies a much larger volume than its ingredients. The result is heave of a stabilized subgrade weeks to months after construction, often in a pattern of humps that is hard to repair. The risk depends on the soluble sulfate content of the soil.
| Soluble sulfate (ppm) | Risk | Typical response |
|---|---|---|
| < 3,000 | Low | Ordinary lime or cement stabilization |
| 3,000 to 5,000 | Moderate | Extended mellowing (24 to 72 hr) after lime and water; extra water; or alternative stabilizer |
| 5,000 to 8,000 | Moderate to high | Double application with mellowing, or non-calcium stabilizer; project-specific testing |
| > 8,000 | High | Avoid calcium-based stabilization; remove and replace or use mechanical stabilization |
Sulfate in clay is often patchy, concentrated in gypsum crystals and seams. Sample at close spacing along the alignment and test the soluble sulfate (for example, TxDOT Tex-145-E or AASHTO T 290). Water used in construction can also bring sulfate in; test it too. Stabilization methods are described in Chapter 7.2 and Chapter 7.3.
Pyrite (FeS2) is common in dark shales, coal measures and some slates and organic clays. While it stays buried below the water table it is stable. When a cut or excavation exposes it to air and water it oxidizes, producing sulfuric acid, iron hydroxide staining and sulfate. The consequences are:
Screening tests include total sulfur, pyritic sulfur, acid-base accounting (acid-producing potential vs. neutralizing potential) and paste pH. Do not use pyritic shale as structural fill under slabs or behind walls, and do not let pyritic spoil drain to streams without treatment.
Many shales, mudstones and claystones are rock in the boring and soil a few seasons after the cut is opened. Wetting and drying, unloading and frost break them down along bedding, and the debris accumulates in ditches, fouls ballast and falls on the track. Durability is measured by the slake durability index (ASTM D4644, withdrawn 2025), with the second-cycle value Id2 usually reported.
| Id2 (%) | Durability | Behavior in cuts and fills |
|---|---|---|
| 0 to 30 | Very low | Degrades to soil within months; treat as soil for slopes and fill |
| 31 to 60 | Low | Slakes in a few seasons; flatten cuts or protect faces |
| 61 to 85 | Medium | Gradual surface degradation; ditch cleaning |
| 86 to 95 | High | Durable with normal design |
| 96 to 100 | Very high | Durable |
Low-durability mudrocks placed as rockfill break down after placement and cause settlement of the embankment, so they should be compacted in thin lifts as soil. In cuts, design benches and ditches to catch debris, and consider shotcrete or vegetation for faces in very low durability rock. Rock slope stability is covered in Chapter 2.7.
| Concern | Test | Sample |
|---|---|---|
| Sulfate attack on concrete | Water-soluble sulfate (soil); sulfate (water); pH; chloride | Soil at foundation and culvert levels; groundwater |
| Sulfate heave with lime or cement | Soluble sulfate at close spacing; trial mix swell test | Subgrade to depth of stabilization |
| Pyrite oxidation | Total and pyritic sulfur; acid-base accounting; paste pH | Dark shales, coal measures, organic clays |
| Mudrock durability | Slake durability (ASTM D4644, withdrawn 2025); jar slake test | Fresh core from the cut |
| Corrosion of steel | Resistivity, pH, chloride, sulfate | Soil and water at pile and anchor depths |
These tests are inexpensive and are best added to the laboratory program from the start (Chapter 5.2), since resampling after a problem appears is costly.
A new box culvert and a lime-stabilized subgrade are planned in a gray clay with visible gypsum crystals. The laboratory reports water-soluble sulfate of 4,200 ppm in the clay at culvert level and 3,600 ppm in the subgrade samples.
| Variable | Value | Description |
|---|---|---|
| SO4 (culvert) | 4,200 ppm | Water-soluble sulfate in clay at culvert level |
| SO4 (subgrade) | 3,600 ppm | Highest value in the stabilization zone |
| Conversion | 1% = 10,000 ppm | Percent by mass to ppm |
| Exposure limits | Table 2.12-1 | Sulfate exposure classes |
| Lime limits | Table 2.12-2 | Sulfate heave risk bands |
The culvert is in exposure class S2 (high sulfate resistance, w/cm ≤ 0.45, f′c ≥ 4,500 psi). The subgrade is at moderate sulfate heave risk: ordinary lime stabilization is not suitable without extended mellowing or an alternative.
The culvert specification should name class S2 so that the precast supplier uses sulfate-resisting cement and the required water-cement ratio. Backfill around the culvert should not be lime- or cement-treated clay from the same deposit.
For the subgrade, the options are a lime application with 48 to 72 hours of mellowing at extra moisture before compaction, supported by a laboratory swell test on the actual soil, or a mechanical stabilization (geogrid and granular section) that avoids calcium altogether. Because sulfate in gypsiferous clay is patchy, more samples along the alignment are needed before choosing: a single 8,000 ppm pocket would rule out lime.
Related chapters in this manual:
Related ICE Manual chapters are listed in the Further Reading box at the top of this chapter and in Appendix G.