↑ Parent Menu⌂ Main Menu
← Chapter 2.10 Non-Engineered Fills: Old Embankments, Waste and Made Ground
GHRM
Railway Ground Hazard Risk Management · 2.0 · The Underworld
Sections · open a dropdown to go to a section or subsection

2.10.2 Investigating Fills

Most of the railroad network sits on fill placed before modern compaction control. This chapter covers how to characterize it and how it behaves.
Author: Daniel P. Colwell
2.10.2 Investigating Fills

Fill variability is the governing problem, so investigation should aim to define the range of conditions rather than a single average profile.

  • Log fill and natural ground as separate units, and record the fill-to-native contact; the old ground surface is often a weak organic layer and a preferred slip surface.
  • Use test pits where access allows: they show debris, voids, timbers and the fill structure that a 2-in. split spoon cannot.
  • Supplement borings with continuous methods along the embankment, such as dynamic cone penetrometer soundings, CPT or ground-penetrating radar for the ballast and subballast section (Chapter 5.1).
  • Expect SPT values to be erratic. A single high blow count on a cobble or tie can mask a loose zone; record and discuss the scatter rather than averaging it away.
  • Sample for organic content, and for chemistry where cinders, slag or industrial waste are present (sulfates and leachable metals; see Chapters 2.12 and 5.4).
  • Install piezometers where the fill may hold perched water; old embankments frequently trap water above a clay core or the original ground surface.

Spacing of explorations in fill should be closer than in natural ground of the same apparent uniformity. Where only a few borings are possible, put them where the history says conditions change: at old trestle locations, culverts, widenings and the ends of cuts.

← Previous · 2.0 The Underworld Chapter 2.9 — Collapsible Soils: Identification, Testing and Railroad Impacts
Next · 2.0 The Underworld → Chapter 2.11 — Soluble Ground and Karst: Sinkholes, Voids and Dissolution