↑ Parent Menu⌂ Main Menu
← Chapter 5.5 The Observational Method and Trigger-Action Response Plans
GHRM
Railway Ground Hazard Risk Management · 5.0 · Testing
Sections · open a dropdown to go to a section or subsection

5.5.2 Choosing What to Measure

Designing for the most probable conditions, measuring what actually happens, and having the response ready before the measurements arrive.
Author: Daniel P. Colwell
5.5.2 Choosing What to Measure
Table 5.5-2. Common observed quantities on railroad ground hazard sites
HazardQuantityInstrument
Embankment on soft groundSettlement, pore pressure, lateral toe movementSettlement plates, piezometers, inclinometers
Slow-moving landslideDisplacement rate at the slip surface, groundwater levelInclinometers, ShapeArrays, piezometers, survey prisms
Cut slope in rockCrack opening, rockfall countsCrackmeters, extensometers, inspection
Retaining structureWall movement, anchor loadsSurvey, tiltmeters, load cells
Any hazard under trafficTrack geometry (surface, cross-level, alignment)Track geometry car, manual measurements
Rainfall-triggered hazardsRainfall intensity and antecedent rainfall, river stageRain gauges, stream gauges, forecasts

Instrumentation types and installation are covered in Chapter 5.3. The measurement should be directly related to the mechanism: for a landslide, displacement at the slip surface and the groundwater level that drives it.

← Previous · 5.0 Testing Chapter 5.4 — Geo-Environmental Testing on Railroad Corridors
Next · 6.0 Analysis → Chapter 6.1 — Foundation Engineering: Bearing Capacity