↑ Parent Menu⌂ Main Menu
← Chapter 1.0 Manual Overview
GHRM
Railway Ground Hazard Risk Management · 1.0 · Introduction
Sections · click a car to open it

1.0.4 Conventions and Standards Basis

About this manual and how it is organized.
Authors: Daniel P. Colwell and Mario Ruel
1.0.4 Conventions and Standards Basis
  • Units: English (U.S. customary) units throughout, with SI in parentheses where a source equation is SI-based.
  • Loading: Cooper E-80 and 286,000-lb gross rail load are the default design bases unless the client specifies otherwise.
  • Governing references: AREMA Manual for Railway Engineering; FRA Track Safety Standards (49 CFR Part 213) and Bridge Safety Standards (49 CFR Part 237); ASTM test methods; FHWA and USACE guidance; and each client railroad's engineering standards, which govern where they differ.
  • Client values: Client-specific criteria quoted in this manual are summaries for planning. Always confirm them against the client's current standard before use on a project.

Reading European (UIC / EN) railway sources alongside AREMA

Several sections of this manual draw on Profillidis, Railway Management and Engineering, which is written to UIC and European (EN) practice in metric units. AREMA and FRA remain the governing basis for North American work; the European material is included for the mechanics, the data and the design logic behind it. The terms and units below appear wherever that material is cited.

Table 1.0-1. Terms and units used where this manual cites Profillidis
European / UIC termNorth American equivalent or conversion
SleeperTie (crosstie)
Track bedBallast + subballast together
Formation layerEngineered top-of-subgrade layer; comparable in role to a blanket or prepared subgrade layer
SubsoilNative or embankment fill below the formation layer
Cant / cant deficiencySuperelevation / unbalanced superelevation
Longitudinal, transverse, horizontal defectSurface (profile), cross-level, alignment
t (metric tonne) — axle load1 t = 2,205 lb; a 286,000-lb car on 4 axles ≈ 32.4 t/axle
kp/cm² (kilopond per cm²)1 kp/cm² ≈ 14.2 psi
t/mm (track or layer reaction coefficient)1 t/mm ≈ 56 kip/in.
‰ (per mille) gradient10‰ = 1.0% grade
MGT / million tons of trafficSame concept; UIC counts gross metric tons

UIC axle-load categories for standard gauge: A = 16 t, B = 18 t, C = 20 t, D = 22.5 t (E = 25 t). Profillidis notes that standard-gauge axle loads in the USA are 28–35 tons, so European design charts calibrated to 22–25 tons sit well below North American heavy-haul loading. Track deterioration is reported to grow roughly with Q3 to Q4 (Q = axle load), so a modest axle-load increase produces a much larger increase in damage.

UIC line groups (UIC Code 714R) classify lines by a fictitious daily tonnage Tth that weights freight, locomotive and speed effects: group 1 > 130,000 t/day; group 2 = 80,000–130,000; group 3 = 40,000–80,000; group 4 = 20,000–40,000; group 5 = 5,000–20,000; group 6 < 5,000 t/day. Group 4 is described as representative of most lines worldwide. Several UIC thickness and maintenance rules in this manual are keyed to these groups.

Regulation, specification, code, standard and guideline are not interchangeable. In the book’s usage, regulations and specifications are rules issued by governmental or inter-governmental bodies that impose specific instructions or methods; codes are a form of legislation defining a procedure or performance to be followed; standards are uniform criteria developed by a national or international body and are suggested rather than obligatory; guidelines are non-mandatory recommendations.

After Profillidis (2014), §7.5 (axle and traffic load), §12 footnote (definitions). Conversions added by the authors. Full reference under Supplemental References.

Next · 1.0 Introduction → Chapter 1.1 — Introduction to Railway Ground Hazard Risk Management