If analysis is likely, collect samples during the geotechnical borings rather than remobilizing. Environmental samples need different handling from geotechnical samples:
- Laboratory-supplied clean jars with preservatives as required; volatile samples collected promptly with minimal disturbance.
- Cooling to about 39°F (4°C) and chain-of-custody documentation from collection to the laboratory.
- Holding times: some analyses must start within days; coordinate with the laboratory before mobilizing.
- Composite samples for waste characterization (for example, one composite per stockpile volume specified by the receiving facility).
Analysis packages commonly used for railroad spoil are total petroleum hydrocarbons, PAHs, metals and, for disposal, the leaching procedure required by the receiving facility. The laboratory testing program is covered in Chapter 5.2.
Chemistry samples: how pH, redox, conductivity, sulfate and chloride are measured, holding times, and how drying and storage change results are covered in
Chapter 5.2, Section 5.2.30.