5.4.5 Investigation-Derived Waste and Spoil

What contaminants to expect in railroad ground, how to sample for them during a geotechnical program, and how to manage drilling waste and spoil.
Author: Daniel P. Colwell
5.4.5 Investigation-Derived Waste and Spoil

Drilling generates cuttings, drilling fluid and decontamination water. On railroad property these are usually containerized (55-gallon drums) where contamination is possible, then characterized and disposed of. The number of drums is a cost and logistics item that should be in the estimate.

Vc = (π D2 / 4) L n fb(Eq. 5.4-1)
Volume of cuttings: D = hole diameter; L = boring depth; n = number of borings; fb = bulking factor (about 1.2 to 1.3).
Ndrums = Vc / (7.35 cf × fill fraction)(Eq. 5.4-2)
A 55-gallon drum holds 7.35 cf; fill to about 80% to allow handling and closing.

Excavation spoil, fouled ballast and ditch cleanings removed during construction follow the same logic at larger scale: characterize, then reuse on the right-of-way where allowed, or dispose of at a facility that accepts the material. Including the characterization in the geotechnical program avoids delays when the contractor starts excavating.

← Previous · 5.0 Testing Chapter 5.3 — Construction Monitoring and Field Testing
Next · 5.0 Testing → Chapter 5.5 — The Observational Method and Trigger-Action Response Plans