5.4.3 Field Screening and Worker Protection

What contaminants to expect in railroad ground, how to sample for them during a geotechnical program, and how to manage drilling waste and spoil.
Author: Daniel P. Colwell
5.4.3 Field Screening and Worker Protection
  • Review the desktop study for yards, fueling, spills and adjacent industry before drilling; write a site health and safety plan that names the expected contaminants.
  • Screen cuttings and samples with a photoionization detector (PID) and note odor, staining and sheen on the logs.
  • Set action levels in the safety plan (PID readings that trigger respiratory protection or stopping work).
  • Use nitrile gloves for sample handling in ballast and shoulder soils as a routine.
  • Decontaminate drilling tools between borings where contamination is suspected, so material is not carried down the hole.
  • Seal borings with grout where they penetrate a confining layer beneath contaminated ground.
← Previous · 5.0 Testing Chapter 5.3 — Construction Monitoring and Field Testing
Next · 5.0 Testing → Chapter 5.5 — The Observational Method and Trigger-Action Response Plans