Twenty borings, each 30 ft deep, are planned with hollow-stem augers in a rail yard with a history of fueling. The owner requires all cuttings to be drummed and characterized before disposal.
| Variable | Value | Description |
|---|---|---|
| n | 20 | Number of borings |
| L | 30 ft | Depth of each boring |
| D | 8 in. (0.667 ft) | Outside diameter of the auger flights (hole diameter) |
| fb | 1.25 | Bulking factor for cuttings |
| Drum | 55 gal = 7.35 cf, filled to 80% | Usable volume 5.88 cf per drum |
The borings will produce about 262 cf of bulked cuttings, requiring about 45 drums for cuttings alone, before decontamination water.
Carry about 50 drums in the estimate to cover decontamination water and the partly filled last drum at each location, plus one composite characterization sample per group of drums as the receiving facility requires. The drums also need a staging area on railroad property that is clear of tracks and accessible to the disposal contractor; include that in the access and right-of-entry planning.
If the yard history suggests petroleum only, ask the client whether cuttings from borings with clean PID readings can be spread on site. That decision can cut the drum count sharply, but it belongs to the client and its environmental staff, not to the drilling crew.