GHRMCalculators · Chapter 5.3, Section 5.3.19

Concrete Mix and Strength Acceptance

Companion to Chapter 5.3 · Construction Monitoring, Section 5.3.19 Concrete Mix Proportioning and Strength Acceptance. English units throughout.

Sketch of the inputs

concrete-acceptancetest number (in order placed)strength (psi)f′c​f′c​ − 500 psiaverage of 3 consecutiveMix: required f′cr​ from s and n; w/cm limit; tests per day volume; cores if low

Each strength test is checked against f′c − 500 psi and every average of three consecutive tests against f′c; mix proportioning uses the producer standard deviation. Not to scale.

Use and limitations

This calculator implements the method described in the manual section linked above. It is for planning, checking and teaching; design values must come from site-specific data, the governing railroad and agency standards, and the judgment of the responsible engineer.

Sources in the library

GHRM · Railway Ground Hazard Risk Management · Daniel P. Colwell