GHRMCalculators · Chapter 5.3, Section 5.3.2.5

Compaction Test Evaluation

Companion to Chapter 5.3 · Construction Monitoring and Field Testing, Section 5.3.2.5 Compaction Test Evaluation. English units throughout.

Sketch of the inputs

compactionwater content w (%)dry unit weight γd​zero air voids (Gs​)γd,max​wopt​required RC × γd,max​moisture windowfield point (γwet​, wf​)

Proctor curve from the lab points gives γd,max and wopt; the field dry unit weight and water content must fall above the required relative compaction and inside the moisture window. Not to scale.

Use and limitations

This calculator implements the method described in the manual section linked above. It is for planning, checking and teaching; design values must come from site-specific data, the governing railroad and agency standards, and the judgment of the responsible engineer.

Sources in the library

GHRM · Railway Ground Hazard Risk Management · Daniel P. Colwell